Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

159

matching recommendations
Reset
SIC 2542 Partitions And Fixtures, Except Wood
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
HO0101 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $595 $1,174 Implemented
HO0101 # 04 Y:1995 04 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,855 $1,000 Implemented
HO0101 # 05 Y:1995 05 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $254 $580 Implemented
HO0101 # 07 Y:1995 07 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,495 $360 Implemented
KU0450 # 07 Y:1995 07 1995 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,310 $180 Implemented
KU0450 # 08 Y:1995 08 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,246 $165 Implemented
KU0450 # 12 Y:1995 12 1995 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $984 $150 Implemented
WI0205 # 01 Y:1994 01 1994 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $5,212 $11,695 Implemented
WI0205 # 05 Y:1994 05 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,764 $4,492 Implemented
WI0205 # 06 Y:1994 06 1994 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,578 $0 Implemented
WI0205 # 07 Y:1994 07 1994 INSTALL OCCUPANCY SENSORS $961 $450 Implemented
WI0205 # 09 Y:1994 09 1994 REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY $2,074 $500 Implemented
WI0205 # 10 Y:1994 10 1994 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $1,362 $800 Implemented
WI0205 # 11 Y:1994 11 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $977 $500 Implemented
WI0190 # 01 Y:1993 01 1993 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $21,567 $800 Implemented
WI0190 # 02 Y:1993 02 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,245 $500 Implemented
WI0190 # 03 Y:1993 03 1993 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $1,049 $500 Implemented
WI0190 # 09 Y:1993 09 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,892 $2,909 Implemented
WI0190 # 10 Y:1993 10 1993 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,495 $450 Implemented
WI0190 # 11 Y:1993 11 1993 INSTALL OCCUPANCY SENSORS $1,165 $225 Implemented
WI0190 # 13 Y:1993 13 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,124 $320 Implemented
IA0052 # 06 Y:1993 06 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,629 $518 Implemented
IA0052 # 07 Y:1993 07 1993 INSTALL OCCUPANCY SENSORS $2,044 $2,646 Implemented
UD0385 # 01 Y:1992 01 1992 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $38,747 $60,000 Implemented
UD0385 # 03 Y:1992 03 1992 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,703 $0 Implemented