IAC logo
IAC Assessment: WI0205
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: WI0205
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 1994
Principal Product point-of-purchase displays, cabinets
NAICS n/a
SIC 2542 - Partitions And Fixtures, Except Wood
Sales $10,000,000-$50,000,000
# of Employees 85
Plant Area (Sq.Ft.) 130,000
Annual Production 3,000,000 Pounds
Production Hrs. Annual 3,250
Location (State) IL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $106,523 1,094,666 kWh $0.10
Natural Gas $72,301 22,352 MMBtu $3.23
TOTAL ENERGY COSTS $178,824
RECOMMENDED SAVINGS* $40,599 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $15,928
#|Description Savings
Cost
Status Electricity Usage Natural Gas Solid Waste (non-haz) Electricity Usage Natural Gas Solid Waste (non-haz)
$ kWh $ MMBtu $ lb
01: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$5,212
Cost:
$11,695
- - $5,212 1,614 - - -
-
kWh
$5,212
1,614
MMBtu
-
-
lb
02: 2.2612 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION Savings:
$3,751
Cost:
$15,000
$3,751 - - - - - $3,751
-
kWh
-
-
MMBtu
-
-
lb
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,651
Cost:
-
$1,651 16,999 - - - - $1,651
16,999
kWh
-
-
MMBtu
-
-
lb
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$578
Cost:
$1,000
- - $578 179 - - -
-
kWh
$578
179
MMBtu
-
-
lb
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,764
Cost:
$4,492
$2,764 28,429 - - - - $2,764
28,429
kWh
-
-
MMBtu
-
-
lb
06: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$2,578
Cost:
-
$2,578 26,377 - - - - $2,578
26,377
kWh
-
-
MMBtu
-
-
lb
07: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$961
Cost:
$450
$961 9,965 - - - - $961
9,965
kWh
-
-
MMBtu
-
-
lb
08: 2.3135 SCHEDULE ROUTINE MAINTENANCE DURING NON-OPERATING PERIODS Savings:
$2,321
Cost:
-
$2,321 - - - - - $2,321
-
kWh
-
-
MMBtu
-
-
lb
09: 2.6241 REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY Savings:
$2,074
Cost:
$500
$907 9,379 $1,167 361 - - $907
9,379
kWh
$1,167
361
MMBtu
-
-
lb
10: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$1,362
Cost:
$800
$1,362 - - - - - $1,362
-
kWh
-
-
MMBtu
-
-
lb
11: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$977
Cost:
$500
- - $977 303 - - -
-
kWh
$977
303
MMBtu
-
-
lb
12: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS Savings:
$16,370
Cost:
$10,000
- - - - $16,370 - -
-
kWh
-
-
MMBtu
$16,370
-
lb
TOTAL RECOMMENDED Savings:
$40,599
Cost:
$44,437
$16,295 91,149 $7,934 2,457 $16,370 - $16,295
91,149
kWh
$7,934
2,457
MMBtu
$16,370
-
lb
TOTAL IMPLEMENTED Savings:
$15,928
Cost:
$18,437
$8,572 74,150 $7,356 2,278 - - $8,572
74,150
kWh
$7,356
2,278
MMBtu
-
-
lb
Savings
Cost
$ kWh $ MMBtu $ lb
Electricity Usage Natural Gas Solid Waste (non-haz) Electricity Usage Natural Gas Solid Waste (non-haz)