Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

273

matching recommendations
Reset
SIC 259 Miscellaneous Furniture And Fixtures
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0290 # 13 Y:2005 13 2005 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $1,381 $700 Implemented
BD0290 # 14 Y:2005 14 2005 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $406 $450 Implemented
BD0290 # 15 Y:2005 15 2005 METER WASTE WATER $728 $250 Implemented
WI0463 # 01 Y:2004 01 2004 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $75,927 $18,500 Not Implemented
WI0463 # 02 Y:2004 02 2004 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $17,690 $17,690 Not Implemented
WI0463 # 03 Y:2004 03 2004 RECOVER WASTE HEAT FROM EQUIPMENT $15,360 $2,000 Not Implemented
WI0463 # 04 Y:2004 04 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $13,859 $29,148 Not Implemented
WI0463 # 05 Y:2004 05 2004 UPGRADE CONTROLS ON COMPRESSORS $11,920 $12,595 Not Implemented
WI0463 # 06 Y:2004 06 2004 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $7,605 $840 Not Implemented
WI0463 # 07 Y:2004 07 2004 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $6,530 $15,200 Not Implemented
IA0313 # 01 Y:2003 01 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,146 $273 Implemented
IA0313 # 02 Y:2003 02 2003 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,353 $155 Not Implemented
IA0313 # 03 Y:2003 03 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,359 $3,111 Not Implemented
IA0313 # 04 Y:2003 04 2003 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $72 $56 Implemented
IA0313 # 05 Y:2003 05 2003 OPTIMIZE PLANT POWER FACTOR $3,916 $9,234 Implemented
IA0313 # 06 Y:2003 06 2003 AUTOMATE PAYROLL SYSTEM $4,536 $6,400 Implemented
IA0313 # 07 Y:2003 07 2003 INSTALL AUTOMATIC PART STORAGE / RETREVAL SYSTEM $22,682 $35,000 Not Implemented
UU0024 # 01 Y:2002 01 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,471 $30 Implemented
UU0024 # 02 Y:2002 02 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,823 $23,536 Not Implemented
UU0024 # 03 Y:2002 03 2002 RECOVER WASTE HEAT FROM EQUIPMENT $2,165 $1,441 Implemented
UU0024 # 04 Y:2002 04 2002 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $9,256 $4,600 Implemented
UU0024 # 05 Y:2002 05 2002 CONTRACT A WOOD PALLET RECYCLING COMPANY $1,020 $0 Implemented
UU0024 # 06 Y:2002 06 2002 PURCHASE MATERIAL FROM SUPPLIER IN CUSTOMIZED PACKAGING $36,029 $0 Implemented
UU0024 # 07 Y:2002 07 2002 PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST $159,659 $61,750 Not Implemented
UU0024 # 08 Y:2002 08 2002 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS $58,590 $720 Implemented