Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
113
matching recommendationsSIC | 26 | Paper And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DS0073 # 03 Y:1996 | 03 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,223 | $6,467 | Implemented |
DS0073 # 02 Y:1996 | 02 | 1996 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $11,263 | $340 | Implemented |
DS0073 # 09 Y:1996 | 09 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $7,618 | $2,100 | Implemented |
DS0073 # 04 Y:1996 | 04 | 1996 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,106 | $0 | Implemented |
DS0073 # 07 Y:1996 | 07 | 1996 | REPAIR AND ELIMINATE STEAM LEAKS | $19,400 | $1,600 | Implemented |
DS0073 # 08 Y:1996 | 08 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,117 | $300 | Implemented |
DS0073 # 06 Y:1996 | 06 | 1996 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $3,061 | $380 | Implemented |
AR0101 # 03 Y:1996 | 03 | 1996 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,212 | $1,048 | Implemented |
AR0101 # 09 Y:1996 | 09 | 1996 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $36,162 | $0 | Implemented |
AR0101 # 08 Y:1996 | 08 | 1996 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $9,526 | $1,900 | Implemented |
AR0101 # 06 Y:1996 | 06 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $652 | $70 | Implemented |
AR0101 # 04 Y:1996 | 04 | 1996 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $817 | $300 | Implemented |
AR0101 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,857 | $759 | Implemented |
AR0101 # 01 Y:1996 | 01 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,305 | $350 | Implemented |
MS0070 # 04 Y:1996 | 04 | 1996 | DISCONNECT BALLASTS | $2,838 | $40 | Implemented |
MS0070 # 03 Y:1996 | 03 | 1996 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $2,600 | $120 | Implemented |
MS0070 # 05 Y:1996 | 05 | 1996 | REDUCE SCRAP PRODUCTION | $39,200 | $2,000 | Implemented |
NV0066 # 07 Y:1996 | 07 | 1996 | HEAT WATER WITH EXHAUST HEAT | $5,214 | $3,300 | Implemented |
NV0066 # 08 Y:1996 | 08 | 1996 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $3,100 | $0 | Implemented |
NV0066 # 05 Y:1996 | 05 | 1996 | INSTALL OCCUPANCY SENSORS | $245 | $94 | Implemented |
NV0066 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $90 | $31 | Implemented |
NV0066 # 03 Y:1996 | 03 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,462 | $200 | Implemented |
NV0066 # 02 Y:1996 | 02 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,307 | $270 | Implemented |
ND0257 # 05 Y:1996 | 05 | 1996 | TURN OFF EQUIPMENT WHEN NOT IN USE | $164 | $1,344 | Implemented |
ND0257 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $344 | $750 | Implemented |