Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
7,948
matching recommendationsSIC | 26 | Paper And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0213 # 12 Y:2005 | 12 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $153,447 | $120,000 | Implemented |
SU0213 # 13 Y:2005 | 13 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $345 | $446 | Not Implemented |
SU0213 # 14 Y:2005 | 14 | 2005 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $294 | $676 | Not Implemented |
WI0495 # 01 Y:2005 | 01 | 2005 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $162,672 | $360,000 | Not Implemented |
WI0495 # 02 Y:2005 | 02 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,256 | $32,760 | Implemented |
WI0495 # 03 Y:2005 | 03 | 2005 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $3,320 | $360 | Implemented |
WI0495 # 04 Y:2005 | 04 | 2005 | INSTALL AUTOMATIC STACK DAMPER | $2,655 | $3,400 | Not Implemented |
WI0495 # 05 Y:2005 | 05 | 2005 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,165 | $0 | Implemented |
WI0495 # 06 Y:2005 | 06 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,800 | $1,280 | Not Implemented |
WI0495 # 07 Y:2005 | 07 | 2005 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $1,135 | $1,500 | Implemented |
WI0495 # 08 Y:2005 | 08 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $322 | $150 | Not Implemented |
WI0495 # 09 Y:2005 | 09 | 2005 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $242 | $200 | Implemented |
WI0494 # 01 Y:2005 | 01 | 2005 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $3,360 | $11,500 | Not Implemented |
WI0494 # 02 Y:2005 | 02 | 2005 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $12,456 | $16,500 | Not Implemented |
WI0494 # 03 Y:2005 | 03 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,231 | $12,960 | Implemented |
WI0494 # 04 Y:2005 | 04 | 2005 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,060 | $6,060 | Not Implemented |
WI0494 # 05 Y:2005 | 05 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,037 | $1,000 | Not Implemented |
WI0494 # 06 Y:2005 | 06 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $207 | $640 | Not Implemented |
LE0213 # 01 Y:2005 | 01 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $24,825 | $1,344 | Implemented |
LE0213 # 02 Y:2005 | 02 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $22,533 | $6,000 | Implemented |
LE0213 # 03 Y:2005 | 03 | 2005 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $9,703 | $25,000 | Not Implemented |
LE0213 # 04 Y:2005 | 04 | 2005 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $5,279 | $368 | Not Implemented |
LE0213 # 05 Y:2005 | 05 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,792 | $1,000 | Implemented |
LE0213 # 06 Y:2005 | 06 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,694 | $2,000 | Implemented |
LE0213 # 07 Y:2005 | 07 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,384 | $200 | Implemented |