Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
7,948
matching recommendationsSIC | 26 | Paper And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0213 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,210 | $53,880 | Implemented |
IC0102 # 01 Y:2005 | 01 | 2005 | MOVE BOILER TO MORE EFFICIENT LOCATION | $39,466 | $3,500 | Not Implemented |
IC0102 # 02 Y:2005 | 02 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $14,439 | $54,000 | Not Implemented |
IC0102 # 03 Y:2005 | 03 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $9,426 | $6,213 | Not Implemented |
IC0102 # 04 Y:2005 | 04 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,597 | $0 | Not Implemented |
IC0102 # 05 Y:2005 | 05 | 2005 | REPAIR AND ELIMINATE STEAM LEAKS | $16,902 | $2,200 | Not Implemented |
IC0102 # 06 Y:2005 | 06 | 2005 | INCREASE AMOUNT OF CONDENSATE RETURNED | $1,738 | $1,200 | Not Implemented |
IC0102 # 07 Y:2005 | 07 | 2005 | INSTALL STEAM TRAP | $542 | $2,142 | Not Implemented |
IC0102 # 08 Y:2005 | 08 | 2005 | CLOSE OFF UNNEEDED STEAM LINES | $329 | $384 | Not Implemented |
IC0102 # 09 Y:2005 | 09 | 2005 | KEEP BOILER TUBES CLEAN | $3,862 | $776 | Not Implemented |
IC0102 # 10 Y:2005 | 10 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $24,250 | $52,000 | Not Implemented |
IC0102 # 11 Y:2005 | 11 | 2005 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $10,135 | $10,152 | Not Implemented |
IC0102 # 12 Y:2005 | 12 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,208 | $5,000 | Not Implemented |
IC0102 # 13 Y:2005 | 13 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,019 | $220 | Not Implemented |
IC0102 # 14 Y:2005 | 14 | 2005 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $10,924 | $2,500 | Not Implemented |
IC0102 # 15 Y:2005 | 15 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $669 | $168 | Not Implemented |
IC0102 # 16 Y:2005 | 16 | 2005 | DISCONNECT BALLASTS | $29,539 | $2,208 | Not Implemented |
TA0096 # 01 Y:2005 | 01 | 2005 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $13,200 | $25,840 | Not Implemented |
TA0096 # 02 Y:2005 | 02 | 2005 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $12,700 | $5,330 | Not Implemented |
TA0096 # 03 Y:2005 | 03 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $11,500 | $2,340 | Not Implemented |
TA0096 # 04 Y:2005 | 04 | 2005 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $8,870 | $13,400 | Not Implemented |
TA0096 # 05 Y:2005 | 05 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,525 | $7,400 | Not Implemented |
TA0096 # 06 Y:2005 | 06 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,040 | $500 | Implemented |
TA0096 # 07 Y:2005 | 07 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $890 | $0 | Not Implemented |
TA0096 # 08 Y:2005 | 08 | 2005 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $645 | $0 | Not Implemented |