Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

7,948

matching recommendations
Reset
SIC 26 Paper And Allied Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0554 # 03 Y:2004 03 2004 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $48,636 $76,341 Not Implemented
MA0554 # 04 Y:2004 04 2004 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $11,697 $11,100 Not Implemented
MA0554 # 05 Y:2004 05 2004 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $6,330 $8,961 Implemented
MA0554 # 06 Y:2004 06 2004 INSULATE FEEDWATER TANK $1,784 $1,300 Implemented
UM0259 # 01 Y:2004 01 2004 RECOVER WASTE HEAT FROM EQUIPMENT $40,040 $58,000 Not Implemented
UM0259 # 02 Y:2004 02 2004 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $25,534 $43,000 Not Implemented
UM0259 # 03 Y:2004 03 2004 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $20,415 $11,200 Implemented
UM0259 # 04 Y:2004 04 2004 INSTALL / REPAIR INSULATION ON STEAM LINES $12,337 $7,410 Implemented
UM0259 # 05 Y:2004 05 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,545 $75,000 Implemented
UM0259 # 06 Y:2004 06 2004 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $5,375 $6,500 Not Implemented
UM0259 # 07 Y:2004 07 2004 UPGRADE CONTROLS ON COMPRESSORS $3,423 $1,500 Implemented
UM0259 # 08 Y:2004 08 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,205 $825 Implemented
UM0259 # 09 Y:2004 09 2004 REPAIR AND ELIMINATE STEAM LEAKS $1,893 $68 Implemented
UM0259 # 10 Y:2004 10 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,765 $200 Implemented
UM0259 # 11 Y:2004 11 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,700 $1,100 Implemented
UU0062 # 01 Y:2004 01 2004 OPTIMIZE PLANT POWER FACTOR $12,920 $20,250 Not Implemented
UU0062 # 02 Y:2004 02 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,404 $790 Implemented
UU0062 # 03 Y:2004 03 2004 INSTALL SPECTRAL REFLECTORS / DELAMP $380 $280 Not Implemented
UU0062 # 04 Y:2004 04 2004 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $392 $1,990 Not Implemented
UU0062 # 05 Y:2004 05 2004 INSTALL OCCUPANCY SENSORS $1,690 $3,226 Not Implemented
UU0062 # 06 Y:2004 06 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $262 $440 Not Implemented
UU0062 # 07 Y:2004 07 2004 CONDENSE OPERATION INTO ONE BUILDING $2,508,360 $6,420,700 Not Implemented
WV0297 # 01 Y:2004 01 2004 INSULATE BARE EQUIPMENT $121,920 $33,990 Not Implemented
WV0297 # 02 Y:2004 02 2004 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $25,862 $55,500 Not Implemented
WV0297 # 03 Y:2004 03 2004 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $18,874 $6,254 Not Implemented