Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
591
matching recommendationsSIC | 26 | Paper And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0212 # 12 Y:2002 | 12 | 2002 | MINIMIZE WATER USAGE | $219 | $1,000 | Not Implemented |
BD0212 # 13 Y:2002 | 13 | 2002 | INSTALL EQUIPMENT TO MOVE PRODUCT | $182,593 | $180,000 | n/a |
BD0212 # 14 Y:2002 | 14 | 2002 | INSTALL AUTOMATIC PACKING EQUIPMENT | $59,860 | $35,000 | n/a |
BD0212 # 15 Y:2002 | 15 | 2002 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $5,000 | $2,500 | Not Implemented |
BD0212 # 16 Y:2002 | 16 | 2002 | AUTOMATE PAYROLL SYSTEM | $3,016 | $2,495 | Not Implemented |
IC0036 # 01 Y:2002 | 01 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,908 | $13,275 | Not Implemented |
IC0036 # 02 Y:2002 | 02 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,335 | $22,479 | Not Implemented |
IC0036 # 03 Y:2002 | 03 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,457 | $2,900 | Implemented |
IC0036 # 04 Y:2002 | 04 | 2002 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $33,201 | $53,875 | Implemented |
IC0036 # 05 Y:2002 | 05 | 2002 | INSTALL SET-BACK TIMERS | $1,686 | $582 | Not Implemented |
IC0036 # 06 Y:2002 | 06 | 2002 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $50,899 | $6,720 | Implemented |
IC0036 # 07 Y:2002 | 07 | 2002 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $14,346 | $7,100 | Not Implemented |
IC0036 # 08 Y:2002 | 08 | 2002 | AUTOMATE PAYROLL SYSTEM | $54,800 | $9,262 | Implemented |
IC0036 # 09 Y:2002 | 09 | 2002 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $33,746 | $19,500 | Not Implemented |
IC0029 # 05 Y:2002 | 05 | 2002 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $14,179 | $1,500 | Implemented |
IC0029 # 06 Y:2002 | 06 | 2002 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $36,712 | $36,036 | Implemented |
IC0029 # 07 Y:2002 | 07 | 2002 | INSULATE BARE EQUIPMENT | $1,616 | $906 | Implemented |
IC0029 # 08 Y:2002 | 08 | 2002 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $18,000 | $3,280 | Not Implemented |
IC0029 # 09 Y:2002 | 09 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,753 | $49,560 | Not Implemented |
IC0029 # 10 Y:2002 | 10 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,519 | $20,549 | Not Implemented |
IC0029 # 11 Y:2002 | 11 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,182 | $4,751 | Not Implemented |
IC0029 # 12 Y:2002 | 12 | 2002 | INSTALL OCCUPANCY SENSORS | $962 | $2,112 | Not Implemented |
IC0029 # 13 Y:2002 | 13 | 2002 | MODIFY WORKLOAD | $150,000 | $32,000 | Not Implemented |
IC0029 # 14 Y:2002 | 14 | 2002 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $102,000 | $8,500 | Not Implemented |
IC0029 # 01 Y:2002 | 01 | 2002 | INSULATE BARE EQUIPMENT | $1,907 | $3,610 | Implemented |