Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

137

matching recommendations
Reset
SIC 26 Paper And Allied Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LL0249 # 07 Y:2006 07 2006 INSTALL OCCUPANCY SENSORS $5,919 $1,740 Not Implemented
LL0249 # 08 Y:2006 08 2006 INSULATE BARE EQUIPMENT $2,138 $1,422 Not Implemented
LL0157 # 01 Y:2003 01 2003 REPAIR AND ELIMINATE STEAM LEAKS $29,568 $490 Not Implemented
LL0157 # 02 Y:2003 02 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $26,381 $4,905 Not Implemented
LL0157 # 03 Y:2003 03 2003 INCREASE AMOUNT OF CONDENSATE RETURNED $4,189 $6,875 Not Implemented
LL0157 # 04 Y:2003 04 2003 OPTIMIZE PLANT POWER FACTOR $3,129 $17,080 Not Implemented
LL0157 # 05 Y:2003 05 2003 USE PHOTOCELL CONTROLS $1,442 $756 Not Implemented
LL0157 # 06 Y:2003 06 2003 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $19,617 $0 Implemented
LL0157 # 07 Y:2003 07 2003 ELIMINATE/REDUCE AN OPERATION $4,800 $0 Not Implemented
LL0157 # 08 Y:2003 08 2003 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $44,506 $12,900 Not Implemented
LL0157 # 09 Y:2003 09 2003 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $4,938,083 $100,000 Not Implemented
LL0147 # 01 Y:2002 01 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,887 $1,500 Implemented
LL0147 # 02 Y:2002 02 2002 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,034 $0 Not Implemented
LL0147 # 03 Y:2002 03 2002 USE PHOTOCELL CONTROLS $2,355 $421 Implemented
LL0147 # 04 Y:2002 04 2002 INSTALL OCCUPANCY SENSORS $450 $104 Not Implemented
LL0147 # 05 Y:2002 05 2002 CONTRACT A WOOD PALLET RECYCLING COMPANY $9,126 $0 Not Implemented
LL0127 # 01 Y:2002 01 2002 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $36,202 $24,480 Not Implemented
LL0127 # 02 Y:2002 02 2002 USE PHOTOCELL CONTROLS $17,992 $946 Not Implemented
LL0127 # 03 Y:2002 03 2002 INSULATE BARE EQUIPMENT $6,380 $4,526 Implemented
LL0127 # 04 Y:2002 04 2002 REPAIR AND ELIMINATE STEAM LEAKS $6,088 $900 Implemented
LL0127 # 05 Y:2002 05 2002 OPTIMIZE PLANT POWER FACTOR $1,970 $6,440 Implemented
LL0121 # 01 Y:2001 01 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $11,365 $2,160 Implemented
LL0121 # 02 Y:2001 02 2001 OPTIMIZE PLANT POWER FACTOR $4,301 $15,406 Not Implemented
LL0121 # 03 Y:2001 03 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $593 $495 Implemented
LL0121 # 04 Y:2001 04 2001 PAY UTILITY BILLS ON TIME $3,665 $0 Implemented