Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
521
matching recommendationsSIC | 26 | Paper And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0459 # 02 Y:2012 | 02 | 2012 | USE PHOTOCELL CONTROLS | $4,256 | $7,400 | Not Implemented |
SD0459 # 03 Y:2012 | 03 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,717 | $200 | Not Implemented |
SD0459 # 04 Y:2012 | 04 | 2012 | INSTALL OCCUPANCY SENSORS | $1,059 | $845 | Not Implemented |
SD0459 # 05 Y:2012 | 05 | 2012 | USE MINIMUM STEAM OPERATING PRESSURE | $276 | $200 | Implemented |
SF0403 # 09 Y:2011 | 09 | 2011 | USE PHOTOCELL CONTROLS | $912 | $5,037 | Not Implemented |
SF0403 # 08 Y:2011 | 08 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,944 | $9,877 | Implemented |
SF0403 # 07 Y:2011 | 07 | 2011 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $4,142 | $15,378 | Not Implemented |
SF0403 # 06 Y:2011 | 06 | 2011 | INSTALL OCCUPANCY SENSORS | $1,801 | $5,900 | Implemented |
SF0403 # 05 Y:2011 | 05 | 2011 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $5,026 | $14,750 | Not Implemented |
SF0403 # 04 Y:2011 | 04 | 2011 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $8,148 | $20,097 | Not Implemented |
SF0403 # 03 Y:2011 | 03 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $681 | $1,471 | Implemented |
SF0403 # 02 Y:2011 | 02 | 2011 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,307 | $2,006 | Implemented |
SF0403 # 01 Y:2011 | 01 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,239 | $720 | Implemented |
SF0400 # 12 Y:2011 | 12 | 2011 | USE SOLAR HEAT TO MAKE ELECTRICTY | $171,695 | $1,807,809 | Not Implemented |
SF0400 # 11 Y:2011 | 11 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $31,158 | $170,718 | Not Implemented |
SF0400 # 10 Y:2011 | 10 | 2011 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $23,990 | $67,329 | Not Implemented |
SF0400 # 09 Y:2011 | 09 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,700 | $41,732 | Not Implemented |
SF0400 # 08 Y:2011 | 08 | 2011 | OPTIMIZE PLANT POWER FACTOR | $5,731 | $15,119 | Not Implemented |
SF0400 # 07 Y:2011 | 07 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,404 | $22,616 | Not Implemented |
SF0400 # 06 Y:2011 | 06 | 2011 | INSTALL OCCUPANCY SENSORS | $9,933 | $14,699 | Not Implemented |
SF0400 # 05 Y:2011 | 05 | 2011 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $48,251 | $66,975 | Not Implemented |
SF0400 # 04 Y:2011 | 04 | 2011 | INSULATE BARE EQUIPMENT | $6,271 | $2,850 | Not Implemented |
SF0400 # 03 Y:2011 | 03 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,063 | $712 | Not Implemented |
SF0400 # 02 Y:2011 | 02 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,056 | $0 | Not Implemented |
SF0400 # 01 Y:2011 | 01 | 2011 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $6,777 | $0 | Not Implemented |