Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

190

matching recommendations
Reset
SIC 26 Paper And Allied Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OD0121 # 01 Y:1998 01 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,192 $6,908 Implemented
OD0121 # 02 Y:1998 02 1998 INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS $3,843 $9,910 Not Implemented
OD0121 # 03 Y:1998 03 1998 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $241 $420 Implemented
OD0121 # 04 Y:1998 04 1998 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $365 $220 Implemented
OD0121 # 05 Y:1998 05 1998 REPAIR OR REPLACE STEAM TRAPS $672 $110 Implemented
OD0121 # 06 Y:1998 06 1998 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,833 $1,495 Implemented
OD0121 # 07 Y:1998 07 1998 INSTALL STEAM TRAP $1,445 $560 Not Implemented
OD0121 # 08 Y:1998 08 1998 ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM $10,017 $2,800 Implemented
OD0099 # 01 Y:1997 01 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,007 $11,490 Implemented
OD0099 # 02 Y:1997 02 1997 OPERATE BOILERS ON HIGH FIRE SETTING $1,495 $1,495 Implemented
OD0099 # 03 Y:1997 03 1997 USE EXCESS COLD PROCESS FLUID FOR INDUSTRIAL COOLING NEEDS $19,847 $8,500 Not Implemented
OD0091 # 01 Y:1997 01 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,021 $1,495 Implemented
OD0091 # 02 Y:1997 02 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,157 $1,420 Implemented
OD0091 # 03 Y:1997 03 1997 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $9,311 $8,736 Not Implemented
OD0091 # 04 Y:1997 04 1997 $120,126 $46,000 Not Implemented
OD0091 # 05 Y:1997 05 1997 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $13,244 $5,000 Implemented
OD0091 # 06 Y:1997 06 1997 $185,900 $0 Implemented
OD0057 # 01 Y:1996 01 1996 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $6,833 $500 Implemented
OD0057 # 02 Y:1996 02 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,120 $600 Implemented
OD0057 # 03 Y:1996 03 1996 RECOVER WASTE HEAT FROM EQUIPMENT $1,630 $1,950 Implemented
OD0057 # 04 Y:1996 04 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,768 $430 Implemented
OD0057 # 05 Y:1996 05 1996 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,639 $4,232 Not Implemented
OD0057 # 06 Y:1996 06 1996 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $751 $200 Not Implemented
NC0071 # 01 Y:1995 01 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,303 $450 Implemented
NC0071 # 02 Y:1995 02 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $186 $115 Implemented