Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
331
matching recommendationsSIC | 26 | Paper And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0218 # 05 Y:2001 | 05 | 2001 | INSTALL TURBULATORS | $30,777 | $70,000 | n/a |
NC0218 # 06 Y:2001 | 06 | 2001 | INSTALL TURBULATORS | $11,012 | $70,000 | n/a |
NC0218 # 07 Y:2001 | 07 | 2001 | INSTALL TURBULATORS | $23,924 | $70,000 | n/a |
NC0218 # 08 Y:2001 | 08 | 2001 | INSTALL TURBULATORS | $84,109 | $125,000 | n/a |
NC0218 # 09 Y:2001 | 09 | 2001 | INSTALL TURBULATORS | $231,014 | $77,000 | n/a |
NC0218 # 10 Y:2001 | 10 | 2001 | RECOVER AND REUSE COOLING WATER | $319,343 | $25,000 | n/a |
NC0218 # 11 Y:2001 | 11 | 2001 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $86,233 | $120,000 | n/a |
NC0218 # 12 Y:2001 | 12 | 2001 | REPAIR OR REPLACE STEAM TRAPS | $20,883 | $31,350 | n/a |
NC0218 # 13 Y:2001 | 13 | 2001 | REPAIR AND ELIMINATE STEAM LEAKS | $8,528 | $20,000 | n/a |
NC0218 # 14 Y:2001 | 14 | 2001 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $207,849 | $51,229 | n/a |
NC0218 # 15 Y:2001 | 15 | 2001 | PURCHASE APPROPRIATELY SIZED MATERIAL | $500,000 | $600,000 | n/a |
NC0218 # 16 Y:2001 | 16 | 2001 | ADOPT IN-HOUSE MATERIAL GENERATION | $255,405 | $102,000 | n/a |
NC0218 # 17 Y:2001 | 17 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $979 | $1,000 | Not Implemented |
NC0218 # 18 Y:2001 | 18 | 2001 | USE PHOTOCELL CONTROLS | $811 | $1,625 | Not Implemented |
NC0218 # 19 Y:2001 | 19 | 2001 | DEVELOP A REPAIR/REPLACE POLICY | $58,457 | $103,241 | n/a |
NC0218 # 20 Y:2001 | 20 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $210,370 | $299,250 | n/a |
NC0218 # 21 Y:2001 | 21 | 2001 | ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM | $34,468 | $33,000 | n/a |
NC0197 # 01 Y:2000 | 01 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $29,525 | $15,500 | Not Implemented |
NC0197 # 02 Y:2000 | 02 | 2000 | AVOID REWINDING MOTORS MORE THAN TWICE | $722 | $1,569 | Implemented |
NC0197 # 03 Y:2000 | 03 | 2000 | INSTALL TIMERS AND/OR THERMOSTATS | $1,176 | $1,200 | Not Implemented |
NC0197 # 04 Y:2000 | 04 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,310 | $2,478 | Implemented |
NC0197 # 05 Y:2000 | 05 | 2000 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $8,100 | $1,000 | Not Implemented |
NC0197 # 06 Y:2000 | 06 | 2000 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $1,596 | $3,500 | Not Implemented |
NC0197 # 07 Y:2000 | 07 | 2000 | ADOPT IN-HOUSE MATERIAL GENERATION | $97,778 | $1,000 | Implemented |
NC0192 # 01 Y:2000 | 01 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,843 | $10,160 | Not Implemented |