Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

331

matching recommendations
Reset
SIC 26 Paper And Allied Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0192 # 02 Y:2000 02 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,718 $50,100 Not Implemented
NC0192 # 03 Y:2000 03 2000 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $4,432 $3,250 Implemented
NC0192 # 04 Y:2000 04 2000 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $87,421 $288,000 Not Implemented
NC0192 # 05 Y:2000 05 2000 USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING $20,845 $10,000 Not Implemented
NC0174 # 01 Y:1999 01 1999 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $9,777 $2,000 Not Implemented
NC0174 # 02 Y:1999 02 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $504 $150 Implemented
NC0174 # 03 Y:1999 03 1999 ADJUST BURNERS FOR EFFICIENT OPERATION $858 $700 Implemented
NC0174 # 04 Y:1999 04 1999 INSULATE BARE EQUIPMENT $1,535 $1,006 Not Implemented
NC0174 # 05 Y:1999 05 1999 RECOVER WASTE HEAT FROM EQUIPMENT $22,630 $13,000 Implemented
NC0174 # 06 Y:1999 06 1999 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,443 $3,520 Not Implemented
NC0130 # 01 Y:1997 01 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $513 $448 Not Implemented
NC0130 # 02 Y:1997 02 1997 DISCONNECT BALLASTS $474 $750 Not Implemented
NC0130 # 03 Y:1997 03 1997 RECOVER WASTE HEAT FROM EQUIPMENT $1,610 $2,650 Not Implemented
NC0130 # 04 Y:1997 04 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,182 $1,400 Not Implemented
NC0130 # 05 Y:1997 05 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $759 $700 Not Implemented
NC0130 # 06 Y:1997 06 1997 REPAIR AND ELIMINATE STEAM LEAKS $72,505 $200 Not Implemented
NC0130 # 07 Y:1997 07 1997 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $9,082 $5,200 Not Implemented
NC0130 # 08 Y:1997 08 1997 USE COUNTER CURRENT RINSING TO REDUCE WASTE WATER $22,291 $28,000 Not Implemented
NC0130 # 09 Y:1997 09 1997 RECOVER AND REUSE COOLING WATER $109,838 $30,250 Not Implemented
NC0130 # 10 Y:1997 10 1997 REDUCE EXCESSIVE BOILER BLOWDOWN $1,000 $0 Not Implemented
NC0106 # 01 Y:1997 01 1997 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $2,580,000 $750,000 Implemented
NC0106 # 02 Y:1997 02 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,860 $1,488 Implemented
NC0106 # 03 Y:1997 03 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $4,304 $770 Not Implemented
NC0106 # 04 Y:1997 04 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $6,634 $1,200 Implemented
NC0106 # 05 Y:1997 05 1997 REDUCE VENTILATION AIR $21,825 $35,000 Implemented