Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
7,948
matching recommendationsSIC | 26 | Paper And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0350 # 06 Y:2006 | 06 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,094 | $1,000 | Implemented |
WV0350 # 07 Y:2006 | 07 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,063 | $0 | Implemented |
WV0350 # 08 Y:2006 | 08 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,275 | $60 | Not Implemented |
WV0350 # 09 Y:2006 | 09 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,103 | $8,181 | Implemented |
WV0350 # 10 Y:2006 | 10 | 2006 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $3,679 | $1,000 | Implemented |
WV0350 # 11 Y:2006 | 11 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,824 | $330 | Not Implemented |
WV0350 # 12 Y:2006 | 12 | 2006 | BURN WASTE OIL FOR HEAT | $2,316 | $1,180 | Not Implemented |
WV0350 # 13 Y:2006 | 13 | 2006 | DEVELOP A REPAIR/REPLACE POLICY | $1,612 | $735 | Implemented |
WV0350 # 14 Y:2006 | 14 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,174 | $375 | Implemented |
WV0350 # 15 Y:2006 | 15 | 2006 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $454 | $640 | Not Implemented |
WV0350 # 16 Y:2006 | 16 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $438 | $250 | Not Implemented |
WV0350 # 17 Y:2006 | 17 | 2006 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $333 | $0 | Not Implemented |
NC0346 # 01 Y:2006 | 01 | 2006 | ADJUST BURNERS FOR EFFICIENT OPERATION | $38,892 | $2,000 | Implemented |
NC0346 # 02 Y:2006 | 02 | 2006 | REPAIR AND ELIMINATE STEAM LEAKS | $2,868 | $500 | Implemented |
NC0346 # 03 Y:2006 | 03 | 2006 | REPAIR OR REPLACE STEAM TRAPS | $741 | $500 | Implemented |
NC0346 # 04 Y:2006 | 04 | 2006 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $33,467 | $28,785 | Not Implemented |
NC0346 # 05 Y:2006 | 05 | 2006 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $8,141 | $20,000 | Implemented |
NC0346 # 06 Y:2006 | 06 | 2006 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $2,687 | $1,485 | Not Implemented |
NC0346 # 07 Y:2006 | 07 | 2006 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $1,249 | $2,000 | Not Implemented |
NC0346 # 08 Y:2006 | 08 | 2006 | DEVELOP A REPAIR/REPLACE POLICY | $2,023 | $1,654 | Implemented |
NC0346 # 09 Y:2006 | 09 | 2006 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,683 | $0 | Not Implemented |
NC0346 # 10 Y:2006 | 10 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $753 | $50 | Implemented |
NC0346 # 11 Y:2006 | 11 | 2006 | USE PHOTOCELL CONTROLS | $376 | $400 | Implemented |
NC0346 # 12 Y:2006 | 12 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,209 | $1,803 | Not Implemented |
NC0346 # 13 Y:2006 | 13 | 2006 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,332 | $200 | Not Implemented |