Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
190
matching recommendationsSIC | 26 | Paper And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0611 # 05 Y:2018 | 05 | 2018 | DEVELOP A REPAIR/REPLACE POLICY | $2,887 | $5,685 | Implemented |
NC0611 # 06 Y:2018 | 06 | 2018 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,662 | $200 | Implemented |
NC0611 # 02 Y:2018 | 02 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,370 | $200 | Implemented |
NC0611 # 04 Y:2018 | 04 | 2018 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $7,227 | $35,000 | Not Implemented |
NC0611 # 03 Y:2018 | 03 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,064 | $100 | Not Implemented |
NC0611 # 01 Y:2018 | 01 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $58,179 | $92,653 | Implemented |
NC0519 # 12 Y:2014 | 12 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $526 | $160 | Not Implemented |
NC0519 # 01 Y:2014 | 01 | 2014 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $207,427 | $102,000 | Implemented |
NC0519 # 08 Y:2014 | 08 | 2014 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $7,811 | $17,150 | Not Implemented |
NC0519 # 09 Y:2014 | 09 | 2014 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $2,308 | $2,500 | Not Implemented |
NC0519 # 10 Y:2014 | 10 | 2014 | DEVELOP A REPAIR/REPLACE POLICY | $2,323 | $4,256 | Not Implemented |
NC0519 # 06 Y:2014 | 06 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,850 | $500 | Implemented |
NC0519 # 04 Y:2014 | 04 | 2014 | REPAIR AND ELIMINATE STEAM LEAKS | $21,819 | $2,200 | Implemented |
NC0519 # 03 Y:2014 | 03 | 2014 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $104,811 | $52,500 | Implemented |
NC0519 # 07 Y:2014 | 07 | 2014 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,436 | $10,000 | Not Implemented |
NC0519 # 11 Y:2014 | 11 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $664 | $72 | Not Implemented |
NC0519 # 13 Y:2014 | 13 | 2014 | INSTALL OCCUPANCY SENSORS | $792 | $2,118 | Not Implemented |
NC0519 # 02 Y:2014 | 02 | 2014 | REPAIR OR REPLACE STEAM TRAPS | $75,916 | $5,100 | Not Implemented |
NC0519 # 05 Y:2014 | 05 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $67,692 | $258,028 | Implemented |
NC0482 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,366 | $33,811 | Implemented |
NC0482 # 06 Y:2013 | 06 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $11,303 | $4,000 | Not Implemented |
NC0482 # 02 Y:2013 | 02 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $76,174 | $132,415 | Not Implemented |
NC0482 # 08 Y:2013 | 08 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,890 | $100 | Implemented |
NC0482 # 04 Y:2013 | 04 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,981 | $2,248 | Not Implemented |
NC0482 # 03 Y:2013 | 03 | 2013 | INSTALL OCCUPANCY SENSORS | $5,539 | $2,682 | Not Implemented |