ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0266 # 02 Y:1988 | 02 | 1988 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $462 | $0 | Implemented |
UD0266 # 03 Y:1988 | 03 | 1988 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,213 | $7,000 | Not Implemented |
UD0266 # 04 Y:1988 | 04 | 1988 | REPAIR AND ELIMINATE STEAM LEAKS | $21,603 | $5,000 | Implemented |
UD0266 # 06 Y:1988 | 06 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,639 | $11,475 | Implemented |
UD0266 # 07 Y:1988 | 07 | 1988 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $9,266 | $30,000 | Implemented |
UD0266 # 08 Y:1988 | 08 | 1988 | BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT | $155,320 | $875,000 | Not Implemented |
TN0311 # 01 Y:1987 | 01 | 1987 | REDUCE VENTILATION AIR | $12,846 | $0 | Implemented |
TN0311 # 02 Y:1987 | 02 | 1987 | INSTALL TIMERS AND/OR THERMOSTATS | $5,954 | $5,400 | Implemented |
TN0311 # 03 Y:1987 | 03 | 1987 | REPAIR AND ELIMINATE STEAM LEAKS | $2,320 | $190 | Implemented |
TN0311 # 04 Y:1987 | 04 | 1987 | USE MINIMUM STEAM OPERATING PRESSURE | $1,857 | $0 | Not Implemented |
TN0311 # 05 Y:1987 | 05 | 1987 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,094 | $437 | Implemented |
TN0311 # 06 Y:1987 | 06 | 1987 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $994 | $300 | Implemented |
TN0311 # 07 Y:1987 | 07 | 1987 | INSTALL STEAM TRAP | $883 | $1,900 | Not Implemented |
TN0311 # 08 Y:1987 | 08 | 1987 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $624 | $68 | Implemented |
TN0311 # 09 Y:1987 | 09 | 1987 | UTILIZE SENSORS CONTROLLING ROOF AND WALL OPENINGS | $822 | $1,665 | Not Implemented |
TN0311 # 10 Y:1987 | 10 | 1987 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $359 | $0 | Not Implemented |
MA0029 # 01 Y:1985 | 01 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $344 | $94 | Not Implemented |
MA0029 # 02 Y:1985 | 02 | 1985 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $17,454 | $9,015 | Not Implemented |
MA0029 # 03 Y:1985 | 03 | 1985 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,980 | $268 | Not Implemented |
MA0029 # 04 Y:1985 | 04 | 1985 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $636 | $763 | Not Implemented |
MA0029 # 05 Y:1985 | 05 | 1985 | REDUCE FLUID FLOW RATES | $2,655 | $0 | Not Implemented |
MA0029 # 06 Y:1985 | 06 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,968 | $2,000 | Not Implemented |
UD0135 # 06 Y:1984 | 06 | 1984 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $37,591 | $0 | Not Implemented |
UD0135 # 05 Y:1984 | 05 | 1984 | USE DRYING OVEN (BATCH TYPE) ON ALTERNATE DAYS OR OTHER OPTIMUM SCHEDULE TO RUN EQUIPMENT WITH FULL LOADS | $54,580 | $0 | Implemented |
UD0135 # 04 Y:1984 | 04 | 1984 | INSTALL SET-BACK TIMERS | $4,080 | $770 | Implemented |