Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
60
matching recommendationsSIC | 2631 | Paperboard Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0332 # 04 Y:2006 | 04 | 2006 | REPLACE BOILER | $683,163 | $1,003,522 | Not Implemented |
SF0332 # 03 Y:2006 | 03 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,653 | $238 | Not Implemented |
SF0332 # 02 Y:2006 | 02 | 2006 | INSULATE BARE EQUIPMENT | $66,216 | $5,557 | Implemented |
SF0332 # 01 Y:2006 | 01 | 2006 | REPAIR AND ELIMINATE STEAM LEAKS | $10,511 | $0 | Implemented |
IC0114 # 09 Y:2006 | 09 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $10,414 | $65,273 | Implemented |
IC0114 # 13 Y:2006 | 13 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,383 | $9,400 | Implemented |
IC0114 # 12 Y:2006 | 12 | 2006 | REPAIR AND ELIMINATE STEAM LEAKS | $2,000 | $2,800 | Implemented |
IC0114 # 08 Y:2006 | 08 | 2006 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $91,228 | $834,000 | Not Implemented |
IC0114 # 11 Y:2006 | 11 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,400 | $1,200 | Implemented |
IC0114 # 10 Y:2006 | 10 | 2006 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $2,000 | $8,400 | Implemented |
IC0114 # 03 Y:2006 | 03 | 2006 | MINIMIZE BOILER BLOWDOWN WITH BETTER FEEDWATER TREATMENT | $19,000 | $63,000 | Implemented |
IC0114 # 07 Y:2006 | 07 | 2006 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $93,057 | $456,000 | Not Implemented |
IC0114 # 06 Y:2006 | 06 | 2006 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $4,216 | $5,280 | Not Implemented |
IC0114 # 05 Y:2006 | 05 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $8,400 | $16,800 | Not Implemented |
IC0114 # 04 Y:2006 | 04 | 2006 | CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS | $175,000 | $120,400 | Not Implemented |
IC0114 # 02 Y:2006 | 02 | 2006 | CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS | $16,000 | $84,000 | Not Implemented |
IC0114 # 01 Y:2006 | 01 | 2006 | INSTALL TURBULATORS | $42,000 | $7,500 | Not Implemented |
IA0382 # 11 Y:2006 | 11 | 2006 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $4,069 | $75 | Not Implemented |
IA0382 # 12 Y:2006 | 12 | 2006 | TURN OFF EQUIPMENT WHEN NOT IN USE | $7,266 | $720 | Not Implemented |
IA0382 # 13 Y:2006 | 13 | 2006 | REPAIR AND ELIMINATE STEAM LEAKS | $1,292 | $600 | Implemented |
IA0382 # 14 Y:2006 | 14 | 2006 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $19,064 | $1,000 | Implemented |
IA0382 # 15 Y:2006 | 15 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $56,152 | $18,000 | Implemented |
IA0382 # 16 Y:2006 | 16 | 2006 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $3,191 | $900 | Not Implemented |
IA0382 # 22 Y:2006 | 22 | 2006 | REDUCE DEFECTS BY REDUCING PRODUCT TIPPING | $14,500 | $18,000 | Not Implemented |
IA0382 # 21 Y:2006 | 21 | 2006 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,293 | $1,000 | Implemented |