Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
72
matching recommendationsSIC | 265 | Paperboard Containers And Boxes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0358 # 05 Y:2003 | 05 | 2003 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,266 | $4,000 | Implemented |
AS0358 # 04 Y:2003 | 04 | 2003 | INSTALL SPECTRAL REFLECTORS / DELAMP | $221 | $32 | Implemented |
AS0358 # 03 Y:2003 | 03 | 2003 | INSTALL OCCUPANCY SENSORS | $88 | $200 | Not Implemented |
AS0358 # 02 Y:2003 | 02 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,694 | $310 | Implemented |
AS0358 # 01 Y:2003 | 01 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $383 | $1,819 | Not Implemented |
AS0358 # 11 Y:2003 | 11 | 2003 | CLEAR AND RENT EXISTING SPACE | $34,374 | $12,148 | n/a |
AS0300 # 05 Y:2001 | 05 | 2001 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $815,625 | $640 | Implemented |
AS0300 # 04 Y:2001 | 04 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,272 | $60 | Not Implemented |
AS0300 # 03 Y:2001 | 03 | 2001 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,824 | $30 | Implemented |
AS0300 # 02 Y:2001 | 02 | 2001 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,174 | $300 | Implemented |
AS0300 # 01 Y:2001 | 01 | 2001 | INSTALL OCCUPANCY SENSORS | $120 | $525 | Not Implemented |
AS0222 # 12 Y:1998 | 12 | 1998 | CLEAR AND RENT EXISTING SPACE | $67,788 | $3,600 | Not Implemented |
AS0222 # 11 Y:1998 | 11 | 1998 | IMPROVE HANDLING PRACTICES | $5,156 | $850 | Implemented |
AS0222 # 10 Y:1998 | 10 | 1998 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $9,828 | $48,000 | Not Implemented |
AS0222 # 09 Y:1998 | 09 | 1998 | TREAT AND REUSE RINSE WATERS | $18,575 | $800 | Implemented |
AS0222 # 07 Y:1998 | 07 | 1998 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $784 | $480 | Implemented |
AS0222 # 06 Y:1998 | 06 | 1998 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $51,367 | $40,600 | Not Implemented |
AS0222 # 05 Y:1998 | 05 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,487 | $8,291 | Implemented |
AS0222 # 04 Y:1998 | 04 | 1998 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $3,365 | $60 | Implemented |
AS0222 # 03 Y:1998 | 03 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,243 | $120 | Implemented |
AS0222 # 02 Y:1998 | 02 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,087 | $3,745 | Not Implemented |
AS0222 # 01 Y:1998 | 01 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $18,249 | $280 | Implemented |
AS0222 # 08 Y:1998 | 08 | 1998 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $407 | $220 | Implemented |
AS0202 # 03 Y:1997 | 03 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,839 | $12 | Implemented |
AS0202 # 02 Y:1997 | 02 | 1997 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,445 | $8,160 | Not Implemented |