Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
74
matching recommendationsSIC | 265 | Paperboard Containers And Boxes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0482 # 03 Y:2001 | 03 | 2001 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $8,590 | $30,000 | Not Implemented |
MA0482 # 04 Y:2001 | 04 | 2001 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $7,900 | $23,000 | Not Implemented |
MA0482 # 05 Y:2001 | 05 | 2001 | USE RADIANT HEATER FOR SPOT HEATING | $5,430 | $25,000 | Not Implemented |
MA0482 # 06 Y:2001 | 06 | 2001 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,200 | $13,000 | Not Implemented |
MA0482 # 07 Y:2001 | 07 | 2001 | RECYCLE WHITE WATER | $5,000 | $20,000 | Not Implemented |
MA0482 # 08 Y:2001 | 08 | 2001 | METER WASTE WATER | $4,400 | $12,000 | Not Implemented |
MA0482 # 09 Y:2001 | 09 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,040 | $450 | Implemented |
MA0482 # 10 Y:2001 | 10 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,700 | $5,000 | Not Implemented |
MA0482 # 11 Y:2001 | 11 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,500 | $7,000 | Not Implemented |
MA0482 # 12 Y:2001 | 12 | 2001 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $1,000 | $600 | Not Implemented |
MA0465 # 02 Y:2000 | 02 | 2000 | OPTIMIZE PLANT POWER FACTOR | $4,076 | $4,125 | Implemented |
MA0465 # 03 Y:2000 | 03 | 2000 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,682 | $20,325 | Not Implemented |
MA0465 # 04 Y:2000 | 04 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $845 | $528 | Implemented |
MA0465 # 05 Y:2000 | 05 | 2000 | INSTALL / REPAIR INSULATION ON STEAM LINES | $605 | $400 | Implemented |
MA0465 # 01 Y:2000 | 01 | 2000 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $34,550 | $50,000 | Not Implemented |
MA0399 # 01 Y:1997 | 01 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $667 | $75 | Implemented |
MA0378 # 05 Y:1996 | 05 | 1996 | USE MAGNETIC TECHNOLOGY TO TREAT WATER | $3,300 | $9,235 | Not Implemented |
MA0378 # 04 Y:1996 | 04 | 1996 | USE RADIANT HEATER FOR SPOT HEATING | $2,379 | $3,200 | Not Implemented |
MA0378 # 03 Y:1996 | 03 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,699 | $1,415 | Not Implemented |
MA0378 # 02 Y:1996 | 02 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $413 | $272 | Not Implemented |
MA0378 # 01 Y:1996 | 01 | 1996 | INSULATE BARE EQUIPMENT | $6,197 | $3,178 | Not Implemented |
MA0206 # 05 Y:1991 | 05 | 1991 | TURN OFF EQUIPMENT WHEN NOT IN USE | $742 | $0 | Implemented |
MA0206 # 04 Y:1991 | 04 | 1991 | INSTALL SET-BACK TIMERS | $864 | $473 | Implemented |
MA0206 # 03 Y:1991 | 03 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $498 | $145 | Implemented |
MA0206 # 02 Y:1991 | 02 | 1991 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $10,773 | $45,415 | Implemented |