Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
152
matching recommendationsSIC | 265 | Paperboard Containers And Boxes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0425 # 02 Y:2011 | 02 | 2011 | DEVELOP A REPAIR/REPLACE POLICY | $2,202 | $3,750 | Not Implemented |
NC0425 # 12 Y:2011 | 12 | 2011 | DEVELOP STANDARD OPERATING PROCEDURES | $6,300 | $3,000 | Not Implemented |
NC0425 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $347 | $100 | Implemented |
NC0425 # 05 Y:2011 | 05 | 2011 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $420 | $25 | Not Implemented |
NC0425 # 07 Y:2011 | 07 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $491 | $700 | Not Implemented |
NC0425 # 09 Y:2011 | 09 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,465 | $3,975 | Implemented |
NC0425 # 08 Y:2011 | 08 | 2011 | INSTALL OCCUPANCY SENSORS | $630 | $980 | Implemented |
NC0425 # 10 Y:2011 | 10 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,987 | $71,380 | Implemented |
NC0346 # 06 Y:2006 | 06 | 2006 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $2,687 | $1,485 | Not Implemented |
NC0346 # 04 Y:2006 | 04 | 2006 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $33,467 | $28,785 | Not Implemented |
NC0346 # 07 Y:2006 | 07 | 2006 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $1,249 | $2,000 | Not Implemented |
NC0346 # 02 Y:2006 | 02 | 2006 | REPAIR AND ELIMINATE STEAM LEAKS | $2,868 | $500 | Implemented |
NC0346 # 01 Y:2006 | 01 | 2006 | ADJUST BURNERS FOR EFFICIENT OPERATION | $38,892 | $2,000 | Implemented |
NC0346 # 08 Y:2006 | 08 | 2006 | DEVELOP A REPAIR/REPLACE POLICY | $2,023 | $1,654 | Implemented |
NC0346 # 12 Y:2006 | 12 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,209 | $1,803 | Not Implemented |
NC0346 # 03 Y:2006 | 03 | 2006 | REPAIR OR REPLACE STEAM TRAPS | $741 | $500 | Implemented |
NC0346 # 05 Y:2006 | 05 | 2006 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $8,141 | $20,000 | Implemented |
NC0346 # 13 Y:2006 | 13 | 2006 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,332 | $200 | Not Implemented |
NC0346 # 10 Y:2006 | 10 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $753 | $50 | Implemented |
NC0346 # 11 Y:2006 | 11 | 2006 | USE PHOTOCELL CONTROLS | $376 | $400 | Implemented |
NC0346 # 09 Y:2006 | 09 | 2006 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,683 | $0 | Not Implemented |
NC0308 # 04 Y:2005 | 04 | 2005 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $13,767 | $6,500 | Implemented |
NC0308 # 01 Y:2005 | 01 | 2005 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $9,359 | $20,313 | Implemented |
NC0308 # 03 Y:2005 | 03 | 2005 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $15,600 | $1,000 | Not Implemented |
NC0308 # 02 Y:2005 | 02 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,017 | $2,450 | Implemented |