Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,551
matching recommendationsSIC | 265 | Paperboard Containers And Boxes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0217 # 08 Y:2005 | 08 | 2005 | OPTIMIZE PLANT POWER FACTOR | $3,979 | $14,487 | Implemented |
MI0114 # 01 Y:2005 | 01 | 2005 | INSULATE BARE EQUIPMENT | $28,126 | $1,091 | Not Implemented |
MI0114 # 02 Y:2005 | 02 | 2005 | IMPROVE COMBUSTION CONTROL CAPABILITY | $20,574 | $30,050 | Implemented |
MI0114 # 03 Y:2005 | 03 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $28,927 | $27,000 | Not Implemented |
MI0114 # 04 Y:2005 | 04 | 2005 | INSULATE BARE EQUIPMENT | $2,983 | $225 | Implemented |
MI0114 # 05 Y:2005 | 05 | 2005 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $9,790 | $4,360 | Implemented |
MI0114 # 06 Y:2005 | 06 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $9,392 | $77 | Implemented |
MI0114 # 07 Y:2005 | 07 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,896 | $1,074 | Implemented |
MI0114 # 08 Y:2005 | 08 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $3,882 | $0 | Implemented |
MI0114 # 09 Y:2005 | 09 | 2005 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $3,521 | $4,628 | Not Implemented |
IC0102 # 01 Y:2005 | 01 | 2005 | MOVE BOILER TO MORE EFFICIENT LOCATION | $39,466 | $3,500 | Not Implemented |
IC0102 # 02 Y:2005 | 02 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $14,439 | $54,000 | Not Implemented |
IC0102 # 03 Y:2005 | 03 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $9,426 | $6,213 | Not Implemented |
IC0102 # 04 Y:2005 | 04 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,597 | $0 | Not Implemented |
IC0102 # 05 Y:2005 | 05 | 2005 | REPAIR AND ELIMINATE STEAM LEAKS | $16,902 | $2,200 | Not Implemented |
IC0102 # 06 Y:2005 | 06 | 2005 | INCREASE AMOUNT OF CONDENSATE RETURNED | $1,738 | $1,200 | Not Implemented |
IC0102 # 07 Y:2005 | 07 | 2005 | INSTALL STEAM TRAP | $542 | $2,142 | Not Implemented |
IC0102 # 08 Y:2005 | 08 | 2005 | CLOSE OFF UNNEEDED STEAM LINES | $329 | $384 | Not Implemented |
IC0102 # 09 Y:2005 | 09 | 2005 | KEEP BOILER TUBES CLEAN | $3,862 | $776 | Not Implemented |
IC0102 # 10 Y:2005 | 10 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $24,250 | $52,000 | Not Implemented |
IC0102 # 11 Y:2005 | 11 | 2005 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $10,135 | $10,152 | Not Implemented |
IC0102 # 12 Y:2005 | 12 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,208 | $5,000 | Not Implemented |
IC0102 # 13 Y:2005 | 13 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,019 | $220 | Not Implemented |
IC0102 # 14 Y:2005 | 14 | 2005 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $10,924 | $2,500 | Not Implemented |
IC0102 # 15 Y:2005 | 15 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $669 | $168 | Not Implemented |