Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,551
matching recommendationsSIC | 265 | Paperboard Containers And Boxes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0485 # 07 Y:2005 | 07 | 2005 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $390 | $800 | Not Implemented |
WI0485 # 08 Y:2005 | 08 | 2005 | INSTALL OCCUPANCY SENSORS | $354 | $840 | Not Implemented |
NC0308 # 01 Y:2005 | 01 | 2005 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $9,359 | $20,313 | Implemented |
NC0308 # 02 Y:2005 | 02 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,017 | $2,450 | Implemented |
NC0308 # 03 Y:2005 | 03 | 2005 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $15,600 | $1,000 | Not Implemented |
NC0308 # 04 Y:2005 | 04 | 2005 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $13,767 | $6,500 | Implemented |
NC0308 # 05 Y:2005 | 05 | 2005 | ADOPT IN-HOUSE MATERIAL GENERATION | $3,600 | $4,000 | Not Implemented |
NC0308 # 06 Y:2005 | 06 | 2005 | INSTALL OCCUPANCY SENSORS | $1,493 | $2,000 | Implemented |
NC0308 # 07 Y:2005 | 07 | 2005 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $867 | $750 | Implemented |
NC0308 # 08 Y:2005 | 08 | 2005 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $338 | $160 | Implemented |
AS0392 # 01 Y:2005 | 01 | 2005 | MODIFY CURRENT INCENTIVE PROGRAM | $1,000,000 | $891,000 | Not Implemented |
AS0392 # 02 Y:2005 | 02 | 2005 | USE PLASTIC PALLETS INSTEAD OF WOOD | $1,000,000 | $217,560 | Not Implemented |
AS0392 # 03 Y:2005 | 03 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,212 | $16,893 | Not Implemented |
AS0392 # 04 Y:2005 | 04 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,774 | $4,055 | Not Implemented |
AS0392 # 05 Y:2005 | 05 | 2005 | INSULATE BARE EQUIPMENT | $2,942 | $650 | Not Implemented |
AS0392 # 06 Y:2005 | 06 | 2005 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $773 | $700 | Not Implemented |
AS0392 # 07 Y:2005 | 07 | 2005 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $4,689 | $6,000 | Not Implemented |
AS0391 # 01 Y:2005 | 01 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $71,356 | $27,044 | Not Implemented |
AS0391 # 02 Y:2005 | 02 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $56,937 | $10,000 | Not Implemented |
AS0391 # 03 Y:2005 | 03 | 2005 | DEVELOP STANDARD OPERATING PROCEDURES | $121,316 | $80,000 | Not Implemented |
AS0391 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,082 | $14,973 | Not Implemented |
AS0391 # 05 Y:2005 | 05 | 2005 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $14,058 | $5,000 | Not Implemented |
AS0391 # 06 Y:2005 | 06 | 2005 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $14,162 | $625 | Not Implemented |
AS0391 # 07 Y:2005 | 07 | 2005 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $11,974 | $2,667 | Not Implemented |
AS0391 # 08 Y:2005 | 08 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,299 | $3,287 | Not Implemented |