Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,551
matching recommendationsSIC | 265 | Paperboard Containers And Boxes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0078 # 12 Y:2004 | 12 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,626 | $955 | n/a |
IC0078 # 13 Y:2004 | 13 | 2004 | KEEP SOLID FUELS / RAW MATERIALS DRY | $260 | $0 | n/a |
IC0078 # 14 Y:2004 | 14 | 2004 | KEEP SOLID FUELS / RAW MATERIALS DRY | $3,949 | $750 | n/a |
UF0335 # 01 Y:2004 | 01 | 2004 | ADD AREA LIGHTING SWITCHES | $2,525 | $10,670 | Not Implemented |
UF0335 # 02 Y:2004 | 02 | 2004 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $44,300 | $205,000 | Not Implemented |
UF0335 # 03 Y:2004 | 03 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $26,089 | $41,729 | Implemented |
UF0335 # 04 Y:2004 | 04 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,790 | $13,573 | Implemented |
UF0335 # 05 Y:2004 | 05 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,008 | $0 | Not Implemented |
UF0335 # 06 Y:2004 | 06 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,359 | $376 | Implemented |
UF0335 # 07 Y:2004 | 07 | 2004 | OPTIMIZE PLANT POWER FACTOR | $3,237 | $20,000 | Implemented |
NC0275 # 01 Y:2003 | 01 | 2003 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $2,058 | $5,954 | Not Implemented |
NC0275 # 02 Y:2003 | 02 | 2003 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $25,721 | $63,800 | Not Implemented |
NC0275 # 03 Y:2003 | 03 | 2003 | USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING | $12,088 | $7,190 | Not Implemented |
NC0275 # 04 Y:2003 | 04 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,207 | $4,563 | Implemented |
NC0275 # 05 Y:2003 | 05 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $455 | $683 | Implemented |
NC0275 # 06 Y:2003 | 06 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,010 | $4,120 | Not Implemented |
TA0064 # 01 Y:2003 | 01 | 2003 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $9,350 | $1,800 | Implemented |
TA0064 # 02 Y:2003 | 02 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $7,450 | $0 | Not Implemented |
TA0064 # 03 Y:2003 | 03 | 2003 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $4,613 | $0 | Not Implemented |
TA0064 # 04 Y:2003 | 04 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,770 | $0 | Implemented |
TA0064 # 05 Y:2003 | 05 | 2003 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $1,740 | $520 | Implemented |
TA0064 # 06 Y:2003 | 06 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,035 | $0 | Not Implemented |
TA0064 # 07 Y:2003 | 07 | 2003 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $101 | $211 | Implemented |
LE0172 # 01 Y:2003 | 01 | 2003 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $7,875 | $8,500 | Not Implemented |
LE0172 # 02 Y:2003 | 02 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $4,633 | $131 | Not Implemented |