Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,551

matching recommendations
Reset
SIC 265 Paperboard Containers And Boxes
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0237 # 04 Y:2002 04 2002 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,539 $1,024 Implemented
SF0237 # 05 Y:2002 05 2002 INSULATE BARE EQUIPMENT $8,315 $6,667 Implemented
SF0237 # 06 Y:2002 06 2002 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $11,732 $16,065 Not Implemented
SF0237 # 07 Y:2002 07 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $24,405 $58,318 Implemented
SF0237 # 08 Y:2002 08 2002 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $210 $627 Not Implemented
SF0237 # 09 Y:2002 09 2002 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $3,489 $0 Implemented
SF0237 # 10 Y:2002 10 2002 OPTIMIZE PLANT POWER FACTOR $4,500 $5,806 Not Implemented
NC0235 # 01 Y:2002 01 2002 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $17,277 $100 Implemented
NC0235 # 02 Y:2002 02 2002 INSTALL BACK-UP EQUIPMENT $156,500 $1,000 Not Implemented
NC0235 # 03 Y:2002 03 2002 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $12,464 $550 Not Implemented
NC0235 # 04 Y:2002 04 2002 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $30,410 $1,000 Implemented
NC0235 # 05 Y:2002 05 2002 DEVELOP A REPAIR/REPLACE POLICY $23,267 $15,570 Implemented
NC0235 # 06 Y:2002 06 2002 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,171 $2,434 Implemented
NC0235 # 07 Y:2002 07 2002 RECOVER AND REUSE COOLING WATER $213 $500 Not Implemented
NC0232 # 01 Y:2002 01 2002 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $13,002 $800 Implemented
NC0232 # 02 Y:2002 02 2002 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $12,335 $15,000 Not Implemented
NC0232 # 03 Y:2002 03 2002 DEVELOP A REPAIR/REPLACE POLICY $1,645 $1,818 Implemented
NC0232 # 04 Y:2002 04 2002 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $561 $248 Implemented
NC0232 # 05 Y:2002 05 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $740 $150 Implemented
NC0232 # 06 Y:2002 06 2002 KEEP BOILER TUBES CLEAN $596 $1,100 Not Implemented
NC0232 # 07 Y:2002 07 2002 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $4,486 $850 Implemented
LE0136 # 01 Y:2002 01 2002 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,384 $1,200 Not Implemented
LE0136 # 02 Y:2002 02 2002 REPAIR OR REPLACE STEAM TRAPS $34,475 $17,000 Not Implemented
LE0136 # 03 Y:2002 03 2002 RECOVER AND REUSE COOLING WATER $1,527 $2,000 Not Implemented
LE0136 # 04 Y:2002 04 2002 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS $34,222 $60,000 Not Implemented