Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
30
matching recommendationsSIC | 2653 | Corrugated And Solid Fiber Boxes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0170 # 03 Y:1985 | 03 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,755 | $2,656 | Implemented |
KU0170 # 04 Y:1985 | 04 | 1985 | REPAIR AND ELIMINATE STEAM LEAKS | $5,297 | $300 | Implemented |
KU0170 # 05 Y:1985 | 05 | 1985 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,901 | $6,000 | Implemented |
KU0170 # 06 Y:1985 | 06 | 1985 | INCREASE AMOUNT OF CONDENSATE RETURNED | $1,746 | $1,000 | Implemented |
KU0170 # 08 Y:1985 | 08 | 1985 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $2,764 | $700 | Implemented |
KU0170 # 09 Y:1985 | 09 | 1985 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $735 | $30 | Implemented |
KU0170 # 10 Y:1985 | 10 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $606 | $300 | Implemented |
KU0170 # 11 Y:1985 | 11 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $147 | $20 | Implemented |
KU0170 # 14 Y:1985 | 14 | 1985 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $1,514 | $1,300 | Implemented |
KU0170 # 16 Y:1985 | 16 | 1985 | INSULATE BARE EQUIPMENT | $1,000 | $591 | Implemented |
KU0170 # 17 Y:1985 | 17 | 1985 | TURN OFF EQUIPMENT WHEN NOT IN USE | $551 | $0 | Implemented |
KU0170 # 02 Y:1985 | 02 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $29,255 | $18 | Implemented |
LT0026 # 02 Y:1985 | 02 | 1985 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $19,870 | $11,300 | Implemented |
LT0026 # 07 Y:1985 | 07 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $4,208 | $300 | Implemented |
LT0026 # 06 Y:1985 | 06 | 1985 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,239 | $2,800 | Implemented |
LT0026 # 05 Y:1985 | 05 | 1985 | REPAIR AND ELIMINATE STEAM LEAKS | $2,460 | $15 | Implemented |
LT0026 # 04 Y:1985 | 04 | 1985 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,384 | $138 | Implemented |
LT0026 # 03 Y:1985 | 03 | 1985 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $1,340 | $405 | Implemented |
LT0026 # 01 Y:1985 | 01 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,318 | $300 | Implemented |
MA0027 # 01 Y:1985 | 01 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $433 | $398 | Implemented |
MA0027 # 02 Y:1985 | 02 | 1985 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $36,744 | $91,620 | Implemented |
MA0027 # 04 Y:1985 | 04 | 1985 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $33,062 | $18,895 | Implemented |
MA0027 # 05 Y:1985 | 05 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $871 | $60 | Implemented |
UD0161 # 03 Y:1985 | 03 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,398 | $10,864 | Implemented |
UD0161 # 04 Y:1985 | 04 | 1985 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $861 | $1,000 | Implemented |