Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
149
matching recommendationsSIC | 2653 | Corrugated And Solid Fiber Boxes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0391 # 14 Y:2006 | 14 | 2006 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $83,200 | $5,350 | Not Implemented |
MI0114 # 08 Y:2005 | 08 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $3,882 | $0 | Implemented |
MI0114 # 01 Y:2005 | 01 | 2005 | INSULATE BARE EQUIPMENT | $28,126 | $1,091 | Not Implemented |
MI0114 # 02 Y:2005 | 02 | 2005 | IMPROVE COMBUSTION CONTROL CAPABILITY | $20,574 | $30,050 | Implemented |
MI0114 # 03 Y:2005 | 03 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $28,927 | $27,000 | Not Implemented |
MI0114 # 04 Y:2005 | 04 | 2005 | INSULATE BARE EQUIPMENT | $2,983 | $225 | Implemented |
MI0114 # 05 Y:2005 | 05 | 2005 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $9,790 | $4,360 | Implemented |
MI0114 # 06 Y:2005 | 06 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $9,392 | $77 | Implemented |
MI0114 # 09 Y:2005 | 09 | 2005 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $3,521 | $4,628 | Not Implemented |
MI0114 # 07 Y:2005 | 07 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,896 | $1,074 | Implemented |
UF0335 # 07 Y:2004 | 07 | 2004 | OPTIMIZE PLANT POWER FACTOR | $3,237 | $20,000 | Implemented |
UF0335 # 01 Y:2004 | 01 | 2004 | ADD AREA LIGHTING SWITCHES | $2,525 | $10,670 | Not Implemented |
UF0335 # 03 Y:2004 | 03 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $26,089 | $41,729 | Implemented |
UF0335 # 06 Y:2004 | 06 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,359 | $376 | Implemented |
UF0335 # 04 Y:2004 | 04 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,790 | $13,573 | Implemented |
UF0335 # 05 Y:2004 | 05 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,008 | $0 | Not Implemented |
UF0335 # 02 Y:2004 | 02 | 2004 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $44,300 | $205,000 | Not Implemented |
MI0061 # 07 Y:2003 | 07 | 2003 | SIZE AIR HANDLING GRILLS/ DUCT/S COILS TO MINIMIZE AIR RESISTANCE | $27,760 | $2,808 | Not Implemented |
MI0061 # 06 Y:2003 | 06 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $7,157 | $147 | Implemented |
MI0061 # 05 Y:2003 | 05 | 2003 | INSTALL OCCUPANCY SENSORS | $524 | $111 | Implemented |
MI0061 # 04 Y:2003 | 04 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,962 | $6 | Implemented |
MI0061 # 03 Y:2003 | 03 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $974 | $332 | Implemented |
MI0061 # 02 Y:2003 | 02 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,605 | $169 | Not Implemented |
MI0061 # 01 Y:2003 | 01 | 2003 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,497 | $8,673 | Not Implemented |
UF0320 # 07 Y:2003 | 07 | 2003 | INSTALL EQUIPMENT TO MOVE PRODUCT | $70,120 | $150,000 | Not Implemented |