Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
111
matching recommendationsSIC | 2653 | Corrugated And Solid Fiber Boxes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0206 # 13 Y:1998 | 13 | 1998 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $2,096 | $0 | Implemented |
UF0206 # 02 Y:1998 | 02 | 1998 | INSTALL OCCUPANCY SENSORS | $3,113 | $5,880 | Implemented |
UF0206 # 08 Y:1998 | 08 | 1998 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $8,949 | $11,900 | Not Implemented |
UF0206 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,127 | $1,018 | Not Implemented |
UF0206 # 05 Y:1998 | 05 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,741 | $1,160 | Implemented |
UF0206 # 04 Y:1998 | 04 | 1998 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $970 | $0 | Not Implemented |
UM0123 # 03 Y:1998 | 03 | 1998 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $6,709 | $6,300 | Not Implemented |
UM0123 # 02 Y:1998 | 02 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,806 | $500 | Not Implemented |
UM0123 # 01 Y:1998 | 01 | 1998 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,378 | $2,188 | Not Implemented |
UM0123 # 08 Y:1998 | 08 | 1998 | $4,161 | $200 | Not Implemented | |
UM0123 # 04 Y:1998 | 04 | 1998 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,138 | $4,120 | Not Implemented |
UM0123 # 05 Y:1998 | 05 | 1998 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $812 | $800 | Not Implemented |
UM0123 # 06 Y:1998 | 06 | 1998 | METER WASTE WATER | $599 | $900 | Not Implemented |
UM0123 # 07 Y:1998 | 07 | 1998 | $5,200 | $100 | Not Implemented | |
ND0297 # 01 Y:1998 | 01 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,421 | $10,400 | Implemented |
ND0297 # 02 Y:1998 | 02 | 1998 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,131 | $9,600 | Not Implemented |
ND0297 # 03 Y:1998 | 03 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,791 | $14,171 | Implemented |
ND0297 # 05 Y:1998 | 05 | 1998 | $868 | $250 | Not Implemented | |
ND0297 # 09 Y:1998 | 09 | 1998 | DISCONNECT BALLASTS | $194 | $176 | Not Implemented |
ND0297 # 11 Y:1998 | 11 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $73 | $300 | Implemented |
ND0297 # 10 Y:1998 | 10 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $167 | $600 | Not Implemented |
ND0297 # 06 Y:1998 | 06 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $410 | $180 | Implemented |
ND0297 # 07 Y:1998 | 07 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $289 | $240 | Not Implemented |
ND0297 # 08 Y:1998 | 08 | 1998 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $256 | $600 | Not Implemented |
ND0297 # 04 Y:1998 | 04 | 1998 | USE PHOTOCELL CONTROLS | $2,278 | $3,600 | Not Implemented |