IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,531

matching recommendations
Reset
SIC 2653 Corrugated And Solid Fiber Boxes
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0212 # 01 Y:2002 01 2002 REPLACE BOILER $17,844 $70,000 Implemented
BD0212 # 02 Y:2002 02 2002 USE RADIANT HEATER FOR SPOT HEATING $16,703 $20,000 n/a
BD0212 # 03 Y:2002 03 2002 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $11,656 $13,200 n/a
BD0212 # 04 Y:2002 04 2002 INSTALL OCCUPANCY SENSORS $3,764 $3,075 Implemented
BD0212 # 05 Y:2002 05 2002 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,605 $1,100 Implemented
BD0212 # 06 Y:2002 06 2002 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,383 $2,000 Not Implemented
BD0212 # 07 Y:2002 07 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,219 $600 Implemented
BD0212 # 08 Y:2002 08 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $999 $2,975 Not Implemented
BD0212 # 09 Y:2002 09 2002 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $931 $1,000 Implemented
BD0212 # 10 Y:2002 10 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $346 $333 Implemented
BD0212 # 11 Y:2002 11 2002 USE EVAPORATION TO CONCENTRATE MATERIAL $2,259 $3,600 Not Implemented
BD0212 # 12 Y:2002 12 2002 MINIMIZE WATER USAGE $219 $1,000 Not Implemented
BD0212 # 13 Y:2002 13 2002 $182,593 $180,000 n/a
BD0212 # 14 Y:2002 14 2002 $59,860 $35,000 n/a
BD0212 # 15 Y:2002 15 2002 $5,000 $2,500 Not Implemented
BD0212 # 16 Y:2002 16 2002 $3,016 $2,495 Not Implemented
NC0235 # 01 Y:2002 01 2002 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $17,277 $100 Implemented
NC0235 # 02 Y:2002 02 2002 $156,500 $1,000 Not Implemented
NC0235 # 03 Y:2002 03 2002 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $12,464 $550 Not Implemented
NC0235 # 04 Y:2002 04 2002 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $30,410 $1,000 Implemented
NC0235 # 05 Y:2002 05 2002 DEVELOP A REPAIR/REPLACE POLICY $23,267 $15,570 Implemented
NC0235 # 06 Y:2002 06 2002 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,171 $2,434 Implemented
NC0235 # 07 Y:2002 07 2002 RECOVER AND REUSE COOLING WATER $213 $500 Not Implemented
LE0136 # 01 Y:2002 01 2002 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,384 $1,200 Not Implemented
LE0136 # 02 Y:2002 02 2002 REPAIR OR REPLACE STEAM TRAPS $34,475 $17,000 Not Implemented