Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

248

matching recommendations
Reset
SIC 2653 Corrugated And Solid Fiber Boxes
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0235 # 03 Y:2002 03 2002 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $12,464 $550 Not Implemented
NC0235 # 04 Y:2002 04 2002 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $30,410 $1,000 Implemented
NC0235 # 05 Y:2002 05 2002 DEVELOP A REPAIR/REPLACE POLICY $23,267 $15,570 Implemented
NC0235 # 06 Y:2002 06 2002 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,171 $2,434 Implemented
NC0235 # 07 Y:2002 07 2002 RECOVER AND REUSE COOLING WATER $213 $500 Not Implemented
LE0136 # 01 Y:2002 01 2002 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,384 $1,200 Not Implemented
LE0136 # 02 Y:2002 02 2002 REPAIR OR REPLACE STEAM TRAPS $34,475 $17,000 Not Implemented
LE0136 # 03 Y:2002 03 2002 RECOVER AND REUSE COOLING WATER $1,527 $2,000 Not Implemented
LE0136 # 04 Y:2002 04 2002 $34,222 $60,000 Not Implemented
LE0136 # 05 Y:2002 05 2002 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,262 $1,000 Not Implemented
LE0134 # 01 Y:2002 01 2002 OPTIMIZE PLANT POWER FACTOR $10,572 $15,000 Not Implemented
LE0134 # 02 Y:2002 02 2002 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $23,457 $1,500 Implemented
LE0134 # 03 Y:2002 03 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,609 $25,249 Implemented
LE0134 # 04 Y:2002 04 2002 INSTALL OCCUPANCY SENSORS $433 $900 Not Implemented
LE0134 # 05 Y:2002 05 2002 MODERATE COOLING TOWER OUTLET TEMPERATURE $1,721 $245 Not Implemented
LE0134 # 06 Y:2002 06 2002 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,676 $1,200 Implemented
AM0417 # 01 Y:2002 01 2002 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $120,900 $8,000 Implemented
AM0417 # 02 Y:2002 02 2002 OPTIMIZE PLANT POWER FACTOR $32,450 $24,980 Implemented
AM0417 # 03 Y:2002 03 2002 REPAIR AND ELIMINATE STEAM LEAKS $32,210 $4,900 Implemented
AM0417 # 04 Y:2002 04 2002 INSULATE BARE EQUIPMENT $7,230 $1,330 Implemented
AM0417 # 05 Y:2002 05 2002 REPAIR OR REPLACE STEAM TRAPS $3,480 $450 Implemented
AM0417 # 06 Y:2002 06 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,670 $880 Implemented
AM0417 # 07 Y:2002 07 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,100 $780 Implemented
AM0417 # 08 Y:2002 08 2002 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $440 $0 Implemented
AM0417 # 09 Y:2002 09 2002 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $380 $0 Not Implemented