Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
55
matching recommendationsSIC | 2653 | Corrugated And Solid Fiber Boxes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0581 # 01 Y:2016 | 01 | 2016 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $20,175 | $500 | Not Implemented |
NC0581 # 06 Y:2016 | 06 | 2016 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $8,569 | $25,000 | Not Implemented |
NC0581 # 02 Y:2016 | 02 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,986 | $45,747 | Implemented |
NC0581 # 08 Y:2016 | 08 | 2016 | DEVELOP A REPAIR/REPLACE POLICY | $2,508 | $5,865 | Not Implemented |
NC0581 # 07 Y:2016 | 07 | 2016 | BURN WASTE OIL FOR HEAT | $1,336 | $5,400 | Not Implemented |
NC0581 # 05 Y:2016 | 05 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,139 | $3,000 | Not Implemented |
NC0581 # 04 Y:2016 | 04 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $155 | $200 | Implemented |
NC0581 # 03 Y:2016 | 03 | 2016 | USE PHOTOCELL CONTROLS | $1,319 | $1,000 | Not Implemented |
NC0248 # 07 Y:2002 | 07 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $196 | $334 | Implemented |
NC0248 # 06 Y:2002 | 06 | 2002 | INSULATE BARE EQUIPMENT | $982 | $1,936 | Implemented |
NC0248 # 05 Y:2002 | 05 | 2002 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $14,743 | $40,000 | Implemented |
NC0248 # 04 Y:2002 | 04 | 2002 | DEVELOP A REPAIR/REPLACE POLICY | $2,115 | $1,075 | Implemented |
NC0248 # 03 Y:2002 | 03 | 2002 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $8,379 | $7,882 | Implemented |
NC0248 # 01 Y:2002 | 01 | 2002 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $7,487 | $1,000 | Not Implemented |
NC0248 # 02 Y:2002 | 02 | 2002 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $6,087 | $0 | Not Implemented |
NC0097 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,021 | $2,451 | Not Implemented |
NC0097 # 09 Y:1996 | 09 | 1996 | EXPAND OPERATIONS INTO UNUSED SPACE | $13,475 | $0 | Not Implemented |
NC0097 # 08 Y:1996 | 08 | 1996 | INSTALL SYSTEM TO COLLECT SCRAP | $20,250 | $1,000 | Not Implemented |
NC0097 # 07 Y:1996 | 07 | 1996 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $657 | $100 | Not Implemented |
NC0097 # 06 Y:1996 | 06 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $488 | $210 | Not Implemented |
NC0097 # 05 Y:1996 | 05 | 1996 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $11,779 | $11,650 | Not Implemented |
NC0097 # 04 Y:1996 | 04 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $486 | $245 | Not Implemented |
NC0097 # 03 Y:1996 | 03 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $469 | $772 | Not Implemented |
NC0097 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $138 | $700 | Not Implemented |
NC0067 # 11 Y:1995 | 11 | 1995 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $21 | $100 | Implemented |