Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
22
matching recommendationsSIC | 2653 | Corrugated And Solid Fiber Boxes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0452 # 06 Y:2004 | 06 | 2004 | USE OPTIMUM TEMPERATURE | $5,420 | $7,880 | Implemented |
OR0452 # 05 Y:2004 | 05 | 2004 | UPGRADE CONTROLS ON COMPRESSORS | $3,600 | $4,000 | Not Implemented |
OR0452 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $900 | $900 | Implemented |
OR0452 # 03 Y:2004 | 03 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,335 | $4,025 | Not Implemented |
OR0452 # 02 Y:2004 | 02 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,280 | $7,540 | Implemented |
OR0452 # 01 Y:2004 | 01 | 2004 | DEVELOP STANDARD OPERATING PROCEDURES | $106,000 | $0 | Implemented |
OR0298 # 03 Y:1997 | 03 | 1997 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,504 | $7,050 | Not Implemented |
OR0298 # 07 Y:1997 | 07 | 1997 | OPTIMIZE PLANT POWER FACTOR | $1,350 | $3,375 | Not Implemented |
OR0298 # 06 Y:1997 | 06 | 1997 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $10,600 | $81,640 | Not Implemented |
OR0298 # 05 Y:1997 | 05 | 1997 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $17,480 | $2,870 | Not Implemented |
OR0298 # 04 Y:1997 | 04 | 1997 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $3,760 | $18,000 | Not Implemented |
OR0298 # 02 Y:1997 | 02 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,037 | $9,611 | Implemented |
OR0298 # 01 Y:1997 | 01 | 1997 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,780 | $500 | Implemented |
OR0050 # 01 Y:1989 | 01 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,268 | $500 | Implemented |
OR0050 # 09 Y:1989 | 09 | 1989 | OPTIMIZE PLANT POWER FACTOR | $890 | $2,250 | Not Implemented |
OR0050 # 08 Y:1989 | 08 | 1989 | INSTALL / REPAIR INSULATION ON STEAM LINES | $379 | $300 | Implemented |
OR0050 # 07 Y:1989 | 07 | 1989 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $244 | $267 | Not Implemented |
OR0050 # 06 Y:1989 | 06 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $198 | $76 | Implemented |
OR0050 # 05 Y:1989 | 05 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,538 | $546 | Implemented |
OR0050 # 04 Y:1989 | 04 | 1989 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,554 | $650 | Not Implemented |
OR0050 # 03 Y:1989 | 03 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $835 | $250 | Implemented |
OR0050 # 02 Y:1989 | 02 | 1989 | INSULATE BARE EQUIPMENT | $1,546 | $378 | Not Implemented |