Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
46
matching recommendationsSIC | 2657 | Folding Paperboard Boxes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0375 # 02 Y:2009 | 02 | 2009 | INSULATE BARE EQUIPMENT | $2,383 | $460 | Implemented |
SF0375 # 03 Y:2009 | 03 | 2009 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $34,176 | $37,453 | Not Implemented |
SF0375 # 04 Y:2009 | 04 | 2009 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $26,893 | $32,381 | Not Implemented |
SF0375 # 05 Y:2009 | 05 | 2009 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,172 | $3,307 | Not Implemented |
SF0375 # 06 Y:2009 | 06 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $75,147 | $244,092 | Implemented |
SF0375 # 07 Y:2009 | 07 | 2009 | INSTALL OCCUPANCY SENSORS | $10,418 | $41,832 | Implemented |
SF0026 # 08 Y:1994 | 08 | 1994 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,146 | $6,550 | Not Implemented |
SF0026 # 09 Y:1994 | 09 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,858 | $900 | Implemented |
SF0026 # 07 Y:1994 | 07 | 1994 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $273 | $500 | Not Implemented |
SF0026 # 06 Y:1994 | 06 | 1994 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,853 | $400 | Implemented |
SF0026 # 05 Y:1994 | 05 | 1994 | OPTIMIZE PLANT POWER FACTOR | $4,040 | $4,739 | Not Implemented |
SF0026 # 04 Y:1994 | 04 | 1994 | USE SYNTHETIC LUBRICANT | $824 | $0 | Not Implemented |
SF0026 # 03 Y:1994 | 03 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,908 | $210 | Not Implemented |
SF0026 # 02 Y:1994 | 02 | 1994 | INSTALL OCCUPANCY SENSORS | $1,520 | $2,614 | Not Implemented |
SF0026 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $10,579 | $13,778 | Implemented |
SD0056 # 01 Y:1993 | 01 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,009 | $978 | Implemented |
SD0056 # 06 Y:1993 | 06 | 1993 | INSTALL SET-BACK TIMERS | $2,408 | $2,880 | Not Implemented |
SD0056 # 05 Y:1993 | 05 | 1993 | INSTALL SPECTRAL REFLECTORS / DELAMP | $6,987 | $20,500 | Not Implemented |
SD0056 # 04 Y:1993 | 04 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,700 | $199 | Not Implemented |
SD0056 # 03 Y:1993 | 03 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,097 | $0 | Implemented |
SD0056 # 02 Y:1993 | 02 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,029 | $300 | Not Implemented |