Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

589

matching recommendations
Reset
SIC 2657 Folding Paperboard Boxes
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WI0102 # 01 Y:1990 01 1990 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $2,402 $2,500 Implemented
WI0102 # 02 Y:1990 02 1990 RECOVER WASTE HEAT FROM EQUIPMENT $1,684 $900 Implemented
WI0102 # 03 Y:1990 03 1990 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,216 $500 Implemented
WI0102 # 04 Y:1990 04 1990 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $56 $66 Implemented
WI0102 # 05 Y:1990 05 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $362 $759 Not Implemented
WI0102 # 06 Y:1990 06 1990 INSTALL SET-BACK TIMERS $439 $200 Implemented
WI0102 # 07 Y:1990 07 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $999 $705 Implemented
WI0102 # 08 Y:1990 08 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $176 $0 Implemented
WI0102 # 09 Y:1990 09 1990 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $990 $1,400 Not Implemented
WI0102 # 10 Y:1990 10 1990 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $900 $2,000 Not Implemented
WI0102 # 11 Y:1990 11 1990 INSTALL TIMERS AND/OR THERMOSTATS $381 $350 Implemented
UD0325 # 01 Y:1990 01 1990 OPTIMIZE PLANT POWER FACTOR $8,661 $5,500 Implemented
UD0325 # 02 Y:1990 02 1990 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $9,752 $11,000 Implemented
UD0325 # 03 Y:1990 03 1990 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS $1,240 $300 Not Implemented
UD0325 # 04 Y:1990 04 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,774 $27,775 Not Implemented
UD0325 # 05 Y:1990 05 1990 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR $32,480 $60,000 Not Implemented
UD0325 # 06 Y:1990 06 1990 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $7,978 $20,000 Implemented
WI0072 # 01 Y:1989 01 1989 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $3,236 $0 Implemented
WI0072 # 02 Y:1989 02 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $564 $3,238 Not Implemented
WI0072 # 03 Y:1989 03 1989 IMPROVE LUBRICATION PRACTICES $1,866 $0 Implemented
WI0072 # 04 Y:1989 04 1989 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,052 $1,000 Not Implemented
WI0072 # 05 Y:1989 05 1989 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $328 $700 Not Implemented
WI0072 # 06 Y:1989 06 1989 INSTALL TIMERS AND/OR THERMOSTATS $301 $250 Implemented
WI0072 # 07 Y:1989 07 1989 UTILIZE SENSORS CONTROLLING ROOF AND WALL OPENINGS $283 $400 Not Implemented
WI0072 # 08 Y:1989 08 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $165 $0 Not Implemented