Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,181
matching recommendationsSIC | 267 | Misc. Converted Paper Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0585 # 04 Y:1999 | 04 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,121 | $1,162 | n/a |
OK0585 # 05 Y:1999 | 05 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $179 | $360 | n/a |
OK0585 # 06 Y:1999 | 06 | 1999 | INSTALL SET-BACK TIMERS | $507 | $260 | n/a |
OK0585 # 07 Y:1999 | 07 | 1999 | OPTIMIZE LOT SIZES TO REDUCE INVENTORY CARRYING COSTS | $45,623 | $17,000 | n/a |
OK0585 # 08 Y:1999 | 08 | 1999 | HIRE ADDITIONAL PERSONNEL TO REDUCE CHANGEOUT TIME | $147,498 | $25,000 | n/a |
OK0585 # 09 Y:1999 | 09 | 1999 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $1,045 | $0 | n/a |
NV0133 # 01 Y:1999 | 01 | 1999 | REPLACE BOILER | $20,745 | $14,694 | Implemented |
NV0133 # 02 Y:1999 | 02 | 1999 | OPTIMIZE PLANT POWER FACTOR | $3,872 | $5,370 | Not Implemented |
NV0133 # 03 Y:1999 | 03 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $38,194 | $38,194 | Not Implemented |
NV0133 # 04 Y:1999 | 04 | 1999 | USE RADIANT HEATER FOR SPOT HEATING | $6,458 | $7,275 | Not Implemented |
NV0133 # 05 Y:1999 | 05 | 1999 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,917 | $9,200 | Not Implemented |
NV0133 # 06 Y:1999 | 06 | 1999 | PAY UTILITY BILLS ON TIME | $1,013 | $0 | Implemented |
MS0137 # 01 Y:1999 | 01 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $15,259 | $898 | Implemented |
MS0137 # 02 Y:1999 | 02 | 1999 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,522 | $660 | Implemented |
MS0137 # 03 Y:1999 | 03 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,249 | $675 | Not Implemented |
MS0137 # 04 Y:1999 | 04 | 1999 | USE PHOTOCELL CONTROLS | $640 | $463 | Not Implemented |
MS0137 # 05 Y:1999 | 05 | 1999 | PAY BILLS ON TIME TO AVOID LATE FEES | $135 | $25 | Implemented |
MS0137 # 06 Y:1999 | 06 | 1999 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $225,000 | $252,938 | Not Implemented |
HO0205 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,922 | $12,583 | Not Implemented |
HO0205 # 02 Y:1999 | 02 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,560 | $11,408 | Implemented |
HO0205 # 03 Y:1999 | 03 | 1999 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,069 | $0 | Implemented |
HO0205 # 04 Y:1999 | 04 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $8,757 | $5,030 | Implemented |
HO0205 # 05 Y:1999 | 05 | 1999 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,237 | $833 | Not Implemented |
HO0205 # 06 Y:1999 | 06 | 1999 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $24,015 | $27,500 | Not Implemented |
HO0205 # 07 Y:1999 | 07 | 1999 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $18,260 | $24,000 | Implemented |