Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
60
matching recommendationsSIC | 267 | Misc. Converted Paper Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0032 # 08 Y:2008 | 08 | 2008 | USE MINIMUM STEAM OPERATING PRESSURE | $2,065 | $0 | Implemented |
DL0032 # 07 Y:2008 | 07 | 2008 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,521 | $643 | Implemented |
DL0032 # 06 Y:2008 | 06 | 2008 | REPLACE BOILER | $6,100 | $6,100 | Implemented |
DL0032 # 05 Y:2008 | 05 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $8,400 | $7,500 | Implemented |
DL0032 # 04 Y:2008 | 04 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,639 | $31,781 | Implemented |
DL0032 # 03 Y:2008 | 03 | 2008 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $12,400 | $7,000 | Not Implemented |
DL0032 # 01 Y:2008 | 01 | 2008 | REPLACE BOILER | $30,400 | $55,000 | Not Implemented |
DL0032 # 02 Y:2008 | 02 | 2008 | REDUCE VENTILATION AIR | $19,700 | $1,200 | Implemented |
IC0151 # 02 Y:2008 | 02 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,067 | $43,816 | Not Implemented |
IC0151 # 10 Y:2008 | 10 | 2008 | REDUCE VENTILATION AIR | $7,098 | $0 | Not Implemented |
IC0151 # 03 Y:2008 | 03 | 2008 | INSTALL OCCUPANCY SENSORS | $1,046 | $2,392 | Not Implemented |
IC0151 # 04 Y:2008 | 04 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $60 | $38 | Not Implemented |
IC0151 # 05 Y:2008 | 05 | 2008 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $13,149 | $40,438 | Not Implemented |
IC0151 # 06 Y:2008 | 06 | 2008 | UPGRADE CONTROLS ON COMPRESSORS | $33,062 | $0 | Not Implemented |
IC0151 # 07 Y:2008 | 07 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,084 | $0 | Not Implemented |
IC0151 # 08 Y:2008 | 08 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $25,247 | $13,262 | Not Implemented |
IC0151 # 09 Y:2008 | 09 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $17,489 | $7,260 | Not Implemented |
IC0151 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,717 | $87,000 | Not Implemented |
IC0151 # 11 Y:2008 | 11 | 2008 | INSTALL TIMERS AND/OR THERMOSTATS | $4,368 | $0 | Not Implemented |
NC0384 # 02 Y:2008 | 02 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,352 | $100 | Implemented |
NC0384 # 03 Y:2008 | 03 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,929 | $7,700 | Not Implemented |
NC0384 # 05 Y:2008 | 05 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,068 | $271 | Implemented |
NC0384 # 01 Y:2008 | 01 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $10,481 | $5,000 | Implemented |
NC0384 # 06 Y:2008 | 06 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,272 | $5,000 | Implemented |
NC0384 # 04 Y:2008 | 04 | 2008 | DEVELOP A REPAIR/REPLACE POLICY | $1,428 | $3,142 | Not Implemented |