Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
58
matching recommendationsSIC | 267 | Misc. Converted Paper Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0680 # 01 Y:2013 | 01 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $17,930 | $1,310 | Implemented |
CO0680 # 02 Y:2013 | 02 | 2013 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,370 | $31,720 | Not Implemented |
CO0680 # 03 Y:2013 | 03 | 2013 | REPAIR AND ELIMINATE STEAM LEAKS | $490 | $230 | Implemented |
BD0432 # 01 Y:2013 | 01 | 2013 | USE RADIANT HEATER FOR SPOT HEATING | $9,498 | $14,512 | Not Implemented |
BD0432 # 06 Y:2013 | 06 | 2013 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $212 | $40 | Not Implemented |
BD0432 # 07 Y:2013 | 07 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $378 | $20 | Not Implemented |
BD0432 # 02 Y:2013 | 02 | 2013 | ADJUST / MAINTAIN FORK LIFT TRUCKS FOR MOST EFFICIENT OPERATION | $6,185 | $16,000 | Not Implemented |
BD0432 # 03 Y:2013 | 03 | 2013 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,832 | $4,800 | Not Implemented |
BD0432 # 04 Y:2013 | 04 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,312 | $500 | Not Implemented |
BD0432 # 05 Y:2013 | 05 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $793 | $2,777 | Not Implemented |
TT0105 # 06 Y:2013 | 06 | 2013 | COMBINE UTILITY METERS | $25,405 | $5,000 | Not Implemented |
TT0105 # 01 Y:2013 | 01 | 2013 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,590 | $1,500 | Implemented |
TT0105 # 05 Y:2013 | 05 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $566 | $1,364 | Not Implemented |
TT0105 # 02 Y:2013 | 02 | 2013 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $10,000 | $50,000 | Not Implemented |
TT0105 # 03 Y:2013 | 03 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,416 | $10,000 | Not Implemented |
TT0105 # 04 Y:2013 | 04 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $24,521 | $31,163 | Not Implemented |
TT0105 # 07 Y:2013 | 07 | 2013 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $6,670 | $500 | Not Implemented |
OK0858 # 03 Y:2013 | 03 | 2013 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $5,082 | $19,800 | Not Implemented |
OK0858 # 01 Y:2013 | 01 | 2013 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $40,042 | $20,360 | Not Implemented |
OK0858 # 07 Y:2013 | 07 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,717 | $66,757 | Not Implemented |
OK0858 # 02 Y:2013 | 02 | 2013 | INSTALL SET-BACK TIMERS | $1,493 | $172 | Not Implemented |
OK0858 # 08 Y:2013 | 08 | 2013 | DISCONNECT BALLASTS | $6,565 | $3,020 | Not Implemented |
OK0858 # 04 Y:2013 | 04 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $804 | $1,338 | Implemented |
OK0858 # 05 Y:2013 | 05 | 2013 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $32,018 | $268,800 | Not Implemented |
OK0858 # 06 Y:2013 | 06 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,454 | $63,252 | Not Implemented |