Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

113

matching recommendations
Reset
SIC 2671 Paper Coated & Laminated, Packaging
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IC0151 # 03 Y:2008 03 2008 INSTALL OCCUPANCY SENSORS $1,046 $2,392 Not Implemented
IC0151 # 04 Y:2008 04 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $60 $38 Not Implemented
IC0151 # 05 Y:2008 05 2008 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $13,149 $40,438 Not Implemented
IC0151 # 06 Y:2008 06 2008 UPGRADE CONTROLS ON COMPRESSORS $33,062 $0 Not Implemented
IC0151 # 07 Y:2008 07 2008 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,084 $0 Not Implemented
IC0151 # 08 Y:2008 08 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $25,247 $13,262 Not Implemented
IC0151 # 09 Y:2008 09 2008 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $17,489 $7,260 Not Implemented
IC0151 # 10 Y:2008 10 2008 REDUCE VENTILATION AIR $7,098 $0 Not Implemented
IC0151 # 11 Y:2008 11 2008 INSTALL TIMERS AND/OR THERMOSTATS $4,368 $0 Not Implemented
BD0251 # 01 Y:2004 01 2004 INSULATE BARE EQUIPMENT $32,333 $98,853 n/a
BD0251 # 02 Y:2004 02 2004 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $8,924 $8,924 Not Implemented
BD0251 # 03 Y:2004 03 2004 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $7,487 $850 Not Implemented
BD0251 # 04 Y:2004 04 2004 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $7,149 $945 Not Implemented
BD0251 # 05 Y:2004 05 2004 RECOVER WASTE HEAT FROM EQUIPMENT $4,899 $750 Not Implemented
BD0251 # 06 Y:2004 06 2004 INSULATE BARE EQUIPMENT $4,625 $413 Not Implemented
BD0251 # 07 Y:2004 07 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,870 $10,160 n/a
BD0251 # 08 Y:2004 08 2004 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,779 $2,000 Not Implemented
BD0251 # 09 Y:2004 09 2004 USE SYNTHETIC LUBRICANT $2,224 $1,200 Not Implemented
BD0251 # 10 Y:2004 10 2004 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,106 $3,570 Not Implemented
BD0251 # 11 Y:2004 11 2004 INSTALL OCCUPANCY SENSORS $1,202 $2,670 Not Implemented
BD0251 # 12 Y:2004 12 2004 INSTALL OCCUPANCY SENSORS $1,199 $2,100 Not Implemented
BD0251 # 13 Y:2004 13 2004 USE PHOTOCELL CONTROLS $767 $650 Not Implemented
BD0251 # 14 Y:2004 14 2004 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $52,949 $8,000 Not Implemented
IC0036 # 01 Y:2002 01 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,908 $13,275 Not Implemented
IC0036 # 02 Y:2002 02 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,335 $22,479 Not Implemented