IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

123

matching recommendations
Reset
SIC 2675 Die-cut Paper And Board
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0252 # 11 Y:2004 11 2004 $7,020 $2,500 Not Implemented
BD0252 # 12 Y:2004 12 2004 $4,800 $1,000 Implemented
WI0404 # 01 Y:2001 01 2001 $12,000 $0 Implemented
WI0404 # 02 Y:2001 02 2001 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $3,918 $14,500 Not Implemented
WI0404 # 03 Y:2001 03 2001 INSTALL OCCUPANCY SENSORS $798 $2,400 Not Implemented
WI0404 # 04 Y:2001 04 2001 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $728 $1,190 Not Implemented
WI0404 # 05 Y:2001 05 2001 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $668 $1,600 Not Implemented
WI0404 # 06 Y:2001 06 2001 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $256 $640 Not Implemented
WI0404 # 07 Y:2001 07 2001 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $135 $400 Implemented
WI0400 # 01 Y:2001 01 2001 $104,000 $4,000 Not Implemented
WI0400 # 02 Y:2001 02 2001 USE DEMAND CONTROLLER OR LOAD SHEDDER $7,857 $10,000 Not Implemented
WI0400 # 03 Y:2001 03 2001 INSTALL OCCUPANCY SENSORS $1,503 $1,500 Not Implemented
WI0400 # 04 Y:2001 04 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $838 $3,744 Not Implemented
WI0400 # 05 Y:2001 05 2001 INSTALL OCCUPANCY SENSORS $211 $300 Not Implemented
WI0400 # 06 Y:2001 06 2001 REPLACE CLOTH RAGS WITH PAPER TOWELS $1,277 $0 Not Implemented
WI0400 # 07 Y:2001 07 2001 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $738 $2,000 Not Implemented
WI0400 # 08 Y:2001 08 2001 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $605 $640 Implemented
WI0400 # 09 Y:2001 09 2001 INSTALL TIMERS AND/OR THERMOSTATS $209 $400 Implemented
SF0195 # 01 Y:2000 01 2000 UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING $5,651 $3,306 Not Implemented
SF0195 # 02 Y:2000 02 2000 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,324 $1,467 Implemented
SF0195 # 03 Y:2000 03 2000 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $848 $1,200 Not Implemented
SF0195 # 04 Y:2000 04 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,297 $5,880 Implemented
SF0195 # 05 Y:2000 05 2000 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,100 $3,250 Implemented
SF0195 # 06 Y:2000 06 2000 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $124,556 $60,000 Not Implemented
SF0195 # 07 Y:2000 07 2000 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $3,147 $10,300 Not Implemented