Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
233
matching recommendationsSIC | 2679 | Converted Paper Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UW0040 # 02 Y:2010 | 02 | 2010 | KEEP BOILER TUBES CLEAN | $82,215 | $50,000 | Implemented |
UW0040 # 01 Y:2010 | 01 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $977,184 | $420,000 | Implemented |
SU0290 # 14 Y:2010 | 14 | 2010 | OPTIMIZE PLANT POWER FACTOR | $1,087 | $6,486 | Implemented |
SU0290 # 12 Y:2010 | 12 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $139 | $335 | Implemented |
SU0290 # 11 Y:2010 | 11 | 2010 | REDUCE VENTILATION AIR | $7,633 | $10,197 | Implemented |
SU0290 # 09 Y:2010 | 09 | 2010 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $186 | $268 | Implemented |
SU0290 # 08 Y:2010 | 08 | 2010 | INSTALL OCCUPANCY SENSORS | $421 | $357 | Implemented |
SU0290 # 05 Y:2010 | 05 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,690 | $200 | Implemented |
SU0290 # 02 Y:2010 | 02 | 2010 | DISCONNECT BALLASTS | $2,268 | $0 | Implemented |
SU0290 # 01 Y:2010 | 01 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,822 | $0 | Implemented |
UD0804 # 15 Y:2009 | 15 | 2009 | ISOLATE HOT OR COLD EQUIPMENT | $1,306 | $0 | Implemented |
UD0804 # 11 Y:2009 | 11 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,128 | $0 | Implemented |
UD0804 # 08 Y:2009 | 08 | 2009 | KEEP BOILER TUBES CLEAN | $8,490 | $600 | Implemented |
UD0804 # 05 Y:2009 | 05 | 2009 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $17,277 | $500 | Implemented |
UD0804 # 04 Y:2009 | 04 | 2009 | REPAIR OR REPLACE STEAM TRAPS | $23,089 | $4,000 | Implemented |
UD0804 # 03 Y:2009 | 03 | 2009 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $35,001 | $9,000 | Implemented |
UD0804 # 02 Y:2009 | 02 | 2009 | AVOID COOLING OF PROCESS STREAMS OR MATERIALS THAT MUST SUBSEQUENTLY BE HEATED | $38,869 | $12,000 | Implemented |
MA0631 # 03 Y:2008 | 03 | 2008 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $609 | $0 | Implemented |
MA0631 # 02 Y:2008 | 02 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,021 | $0 | Implemented |
MA0631 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,384 | $27,090 | Implemented |
MA0631 # 04 Y:2008 | 04 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $350 | $200 | Implemented |
IC0136 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,802 | $9,080 | Implemented |
IC0136 # 02 Y:2007 | 02 | 2007 | INSTALL OCCUPANCY SENSORS | $2,224 | $5,038 | Implemented |
IC0136 # 04 Y:2007 | 04 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,389 | $3,105 | Implemented |
GT0840 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $515 | $2,301 | Implemented |