Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
63
matching recommendationsSIC | 271 | Newspapers |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0695 # 07 Y:2015 | 07 | 2015 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,350 | $540 | Implemented |
AM0695 # 05 Y:2015 | 05 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $800 | $200 | Implemented |
AM0695 # 04 Y:2015 | 04 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $875 | $520 | Implemented |
AM0695 # 03 Y:2015 | 03 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,170 | $1,660 | Implemented |
AM0695 # 02 Y:2015 | 02 | 2015 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $9,660 | $0 | Implemented |
AM0518 # 01 Y:2006 | 01 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $44,220 | $1,000 | Implemented |
AM0518 # 03 Y:2006 | 03 | 2006 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $4,000 | $415 | Implemented |
AM0518 # 04 Y:2006 | 04 | 2006 | REUSE RAGS UNTIL COMPLETELY SOILED | $3,850 | $0 | Implemented |
AM0518 # 05 Y:2006 | 05 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,280 | $500 | Implemented |
AM0518 # 06 Y:2006 | 06 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $280 | $0 | Implemented |
AM0502 # 02 Y:2006 | 02 | 2006 | REUSE RAGS UNTIL COMPLETELY SOILED | $82,500 | $0 | Implemented |
AM0502 # 14 Y:2006 | 14 | 2006 | USE PHOTOCELL CONTROLS | $200 | $0 | Implemented |
AM0502 # 13 Y:2006 | 13 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $460 | $510 | Implemented |
AM0502 # 11 Y:2006 | 11 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,200 | $2,730 | Implemented |
AM0502 # 10 Y:2006 | 10 | 2006 | INSTALL OCCUPANCY SENSORS | $3,340 | $340 | Implemented |
AM0502 # 09 Y:2006 | 09 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,900 | $1,000 | Implemented |
AM0502 # 08 Y:2006 | 08 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,900 | $1,000 | Implemented |
AM0502 # 03 Y:2006 | 03 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $39,000 | $6,000 | Implemented |
AM0502 # 06 Y:2006 | 06 | 2006 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $6,983 | $0 | Implemented |
AM0502 # 04 Y:2006 | 04 | 2006 | OPTIMIZE PLANT POWER FACTOR | $29,100 | $15,000 | Implemented |
AM0502 # 01 Y:2006 | 01 | 2006 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $288,000 | $675,000 | Implemented |
AM0498 # 05 Y:2005 | 05 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,480 | $770 | Implemented |
AM0498 # 07 Y:2005 | 07 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $830 | $165 | Implemented |
AM0498 # 09 Y:2005 | 09 | 2005 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $700 | $280 | Implemented |
AM0498 # 04 Y:2005 | 04 | 2005 | REUSE RAGS UNTIL COMPLETELY SOILED | $1,580 | $0 | Implemented |