Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
51
matching recommendationsSIC | 275 | Commercial Printing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0955 # 07 Y:2016 | 07 | 2016 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $580 | $2,140 | Implemented |
OK0955 # 09 Y:2016 | 09 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,370 | $11,297 | Implemented |
OK0955 # 06 Y:2016 | 06 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,112 | $1,100 | Implemented |
OK0955 # 04 Y:2016 | 04 | 2016 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,925 | $572 | Implemented |
OK0955 # 03 Y:2016 | 03 | 2016 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $598 | $220 | Implemented |
OK0955 # 02 Y:2016 | 02 | 2016 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $5,478 | $10,800 | Implemented |
OK0708 # 07 Y:2005 | 07 | 2005 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $5,070 | $700 | Implemented |
OK0708 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,450 | $26,280 | Implemented |
OK0708 # 05 Y:2005 | 05 | 2005 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $37,832 | $13,050 | Implemented |
OK0708 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,314 | $1,327 | Implemented |
OK0708 # 02 Y:2005 | 02 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,394 | $6,700 | Implemented |
OK0708 # 01 Y:2005 | 01 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,172 | $6,087 | Implemented |
OK0537 # 07 Y:1997 | 07 | 1997 | RECYCLE WASTE INK AND CLEANUP SOLVENT | $500 | $1,300 | Implemented |
OK0537 # 05 Y:1997 | 05 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $793 | $1,000 | Implemented |
OK0537 # 04 Y:1997 | 04 | 1997 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $33,000 | $65,000 | Implemented |
OK0485 # 05 Y:1996 | 05 | 1996 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $6,970 | $29,500 | Implemented |
OK0485 # 03 Y:1996 | 03 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $428 | $786 | Implemented |
OK0485 # 02 Y:1996 | 02 | 1996 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,827 | $2,730 | Implemented |
OK0478 # 02 Y:1995 | 02 | 1995 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $28,374 | $48,000 | Implemented |
OK0478 # 10 Y:1995 | 10 | 1995 | MINIMIZE CONTAMINATION OF WATER BEFORE TREATMENT | $6,080 | $500 | Implemented |
OK0478 # 09 Y:1995 | 09 | 1995 | SWITCH TO A SOLVENT THAT CAN BE CLEANED AND RE-USED | $8,089 | $4,295 | Implemented |
OK0478 # 11 Y:1995 | 11 | 1995 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $4,300 | $0 | Implemented |
OK0478 # 01 Y:1995 | 01 | 1995 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $63,653 | $25,000 | Implemented |
OK0478 # 08 Y:1995 | 08 | 1995 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,578 | $1,000 | Implemented |
OK0459 # 02 Y:1995 | 02 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $774 | $795 | Implemented |