Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
80
matching recommendationsSIC | 275 | Commercial Printing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OD0148 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,808 | $43,334 | Not Implemented |
OD0148 # 02 Y:1999 | 02 | 1999 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,160 | $1,495 | Not Implemented |
OD0148 # 03 Y:1999 | 03 | 1999 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $446 | $308 | Not Implemented |
OD0148 # 04 Y:1999 | 04 | 1999 | REDUCE VENTILATION AIR | $1,954 | $504 | Not Implemented |
OD0148 # 06 Y:1999 | 06 | 1999 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $368 | $90 | Not Implemented |
OD0148 # 07 Y:1999 | 07 | 1999 | METER WASTE WATER | $4,026 | $4,595 | Not Implemented |
OD0147 # 04 Y:1999 | 04 | 1999 | REPAIR OR REPLACE STEAM TRAPS | $1,854 | $360 | Not Implemented |
OD0147 # 03 Y:1999 | 03 | 1999 | REDUCE VENTILATION AIR | $431 | $126 | Not Implemented |
OD0147 # 02 Y:1999 | 02 | 1999 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $960 | $450 | Not Implemented |
OD0147 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,844 | $3,872 | Not Implemented |
OD0127 # 04 Y:1999 | 04 | 1999 | COMBINE UTILITY METERS | $9,570 | $5,000 | Implemented |
OD0127 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,954 | $5,472 | Implemented |
OD0127 # 02 Y:1999 | 02 | 1999 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $477 | $80 | Not Implemented |
OD0127 # 03 Y:1999 | 03 | 1999 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $3,582 | $240 | Implemented |
OD0116 # 05 Y:1998 | 05 | 1998 | USE SYNTHETIC LUBRICANT | $255 | $255 | Implemented |
OD0116 # 01 Y:1998 | 01 | 1998 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,986 | $1,615 | Not Implemented |
OD0116 # 02 Y:1998 | 02 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $925 | $2,175 | Implemented |
OD0116 # 03 Y:1998 | 03 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $921 | $800 | Implemented |
OD0116 # 04 Y:1998 | 04 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $95 | $91 | Implemented |
OD0061 # 06 Y:1996 | 06 | 1996 | INSTALL OCCUPANCY SENSORS | $408 | $689 | Not Implemented |
OD0061 # 07 Y:1996 | 07 | 1996 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $46 | $0 | Not Implemented |
OD0061 # 08 Y:1996 | 08 | 1996 | CONVERT TO AQUEOUS CLEANING SYSTEM | $3,004 | $5,050 | Not Implemented |
OD0061 # 01 Y:1996 | 01 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $189 | $160 | Not Implemented |
OD0061 # 02 Y:1996 | 02 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $337 | $270 | Not Implemented |
OD0061 # 03 Y:1996 | 03 | 1996 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $11,625 | $5,634 | Not Implemented |