Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,301
matching recommendationsSIC | 275 | Commercial Printing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0324 # 09 Y:2002 | 09 | 2002 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $77,357 | $15,800 | Not Implemented |
AS0324 # 10 Y:2002 | 10 | 2002 | CLEAR AND RENT EXISTING SPACE | $53,920 | $5,308 | Not Implemented |
UM0208 # 01 Y:2002 | 01 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,164 | $650 | Implemented |
UM0208 # 02 Y:2002 | 02 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,036 | $10,015 | Implemented |
UM0208 # 03 Y:2002 | 03 | 2002 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,158 | $100 | Implemented |
UM0208 # 04 Y:2002 | 04 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $484 | $150 | Implemented |
OK0629 # 01 Y:2001 | 01 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $947 | $308 | Implemented |
OK0629 # 02 Y:2001 | 02 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,735 | $180 | Implemented |
OK0629 # 03 Y:2001 | 03 | 2001 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $193,540 | $25,975 | Not Implemented |
OK0629 # 04 Y:2001 | 04 | 2001 | AIR CONDITION ONLY SPACE NECESSARY | $4,536 | $400 | Implemented |
OK0629 # 05 Y:2001 | 05 | 2001 | TURN OFF EQUIPMENT WHEN NOT IN USE | $190 | $0 | Not Implemented |
OK0629 # 06 Y:2001 | 06 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $495 | $374 | Not Implemented |
OK0629 # 07 Y:2001 | 07 | 2001 | INSTALL OCCUPANCY SENSORS | $392 | $627 | Not Implemented |
AM0404 # 01 Y:2001 | 01 | 2001 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $198,000 | $25,000 | Implemented |
AM0404 # 02 Y:2001 | 02 | 2001 | REUSE RAGS UNTIL COMPLETELY SOILED | $12,600 | $0 | Implemented |
AM0404 # 03 Y:2001 | 03 | 2001 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $15,440 | $0 | Not Implemented |
AM0404 # 04 Y:2001 | 04 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,330 | $41,800 | Implemented |
AM0404 # 05 Y:2001 | 05 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,800 | $2,828 | Implemented |
AM0404 # 06 Y:2001 | 06 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,710 | $368 | Implemented |
AM0404 # 07 Y:2001 | 07 | 2001 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $250 | $0 | Implemented |
AM0404 # 08 Y:2001 | 08 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $690 | $765 | Implemented |
LE0125 # 01 Y:2001 | 01 | 2001 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $30,715 | $2,500 | Not Implemented |
LE0125 # 02 Y:2001 | 02 | 2001 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $6,926 | $0 | Implemented |
LE0125 # 03 Y:2001 | 03 | 2001 | IMPROVE LUBRICATION PRACTICES | $1,126 | $400 | Not Implemented |
LE0125 # 04 Y:2001 | 04 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,045 | $0 | Not Implemented |