Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

58

matching recommendations
Reset
SIC 2796 Platemaking Services
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0182 # 01 Y:2000 01 2000 INSTALL OCCUPANCY SENSORS $761 $720 Not Implemented
ND0310 # 04 Y:1998 04 1998 RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS $1,487 $0 Implemented
ND0310 # 10 Y:1998 10 1998 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS $15,186 $42,730 Not Implemented
ND0310 # 09 Y:1998 09 1998 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $2 $0 Not Implemented
ND0310 # 07 Y:1998 07 1998 INSTALL OCCUPANCY SENSORS $1,001 $600 Not Implemented
ND0310 # 06 Y:1998 06 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $501 $880 Not Implemented
ND0310 # 05 Y:1998 05 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,890 $8,263 Not Implemented
ND0310 # 03 Y:1998 03 1998 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $56,650 $65,000 Implemented
ND0310 # 02 Y:1998 02 1998 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $27,164 $9,600 Implemented
ND0310 # 01 Y:1998 01 1998 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $9,419 $24,900 Implemented
ND0310 # 08 Y:1998 08 1998 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $60 $200 Not Implemented
MA0226 # 02 Y:1991 02 1991 INSTALL TIMERS AND/OR THERMOSTATS $6,376 $0 Implemented
MA0226 # 01 Y:1991 01 1991 MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE $11,242 $21,238 Implemented
MA0226 # 03 Y:1991 03 1991 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $5,696 $0 Implemented
MA0226 # 04 Y:1991 04 1991 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $3,079 $9,000 Implemented
MA0226 # 05 Y:1991 05 1991 INSULATE BARE EQUIPMENT $3,303 $856 Implemented
MA0226 # 06 Y:1991 06 1991 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $255 $3,020 Implemented
MA0216 # 08 Y:1991 08 1991 INSTALL SET-BACK TIMERS $472 $398 Implemented
MA0216 # 07 Y:1991 07 1991 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $472 $193 Implemented
MA0216 # 06 Y:1991 06 1991 RECOVER WASTE HEAT FROM EQUIPMENT $1,800 $590 Implemented
MA0216 # 05 Y:1991 05 1991 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $307 $1,189 Implemented
MA0216 # 04 Y:1991 04 1991 INSTALL TIMERS AND/OR THERMOSTATS $3,188 $3,548 Implemented
MA0216 # 03 Y:1991 03 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,673 $8,000 Implemented
MA0216 # 02 Y:1991 02 1991 OPTIMIZE PLANT POWER FACTOR $6,750 $23,400 Implemented
MA0216 # 01 Y:1991 01 1991 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $9,534 $22,880 Implemented