Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
622
matching recommendationsSIC | 28 | Chemicals And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LM0046 # 06 Y:2003 | 06 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $5,314 | $0 | Implemented |
LM0046 # 07 Y:2003 | 07 | 2003 | INSTALL OCCUPANCY SENSORS | $2,760 | $521 | Implemented |
LM0046 # 08 Y:2003 | 08 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,802 | $17,200 | Not Implemented |
LM0046 # 09 Y:2003 | 09 | 2003 | INSTALL TIMERS AND/OR THERMOSTATS | $17,717 | $120 | Not Implemented |
LM0046 # 10 Y:2003 | 10 | 2003 | RECOVER AND REUSE COOLING WATER | $40,647 | $5,000 | Implemented |
LM0046 # 11 Y:2003 | 11 | 2003 | UTILIZE OUTSIDE CONTRACTING | $56,838 | $11,800 | Not Implemented |
LM0046 # 12 Y:2003 | 12 | 2003 | UTILIZE OUTSIDE CONTRACTING | $234,229 | $100,000 | Not Implemented |
LM0046 # 13 Y:2003 | 13 | 2003 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $230,000 | $336,269 | Implemented |
SF0252 # 01 Y:2003 | 01 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,775 | $500 | Implemented |
SF0252 # 02 Y:2003 | 02 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $636 | $814 | Not Implemented |
SF0252 # 03 Y:2003 | 03 | 2003 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $2,342 | $4,612 | Not Implemented |
SF0252 # 04 Y:2003 | 04 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $846 | $2,550 | Implemented |
SF0252 # 05 Y:2003 | 05 | 2003 | INSTALL WIND POWERED ELECTRIC GENERATOR | $23,641 | $205,000 | Not Implemented |
SF0248 # 01 Y:2002 | 01 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,662 | $0 | Implemented |
SF0248 # 02 Y:2002 | 02 | 2002 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $9,169 | $1,436 | Not Implemented |
SF0248 # 03 Y:2002 | 03 | 2002 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $1,713 | $1,685 | Implemented |
SF0248 # 04 Y:2002 | 04 | 2002 | USE PHOTOCELL CONTROLS | $5,341 | $6,000 | Implemented |
SF0248 # 05 Y:2002 | 05 | 2002 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $513 | $700 | Not Implemented |
SF0248 # 06 Y:2002 | 06 | 2002 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $2,409 | $13,000 | Implemented |
SF0248 # 07 Y:2002 | 07 | 2002 | REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT | $840 | $0 | Not Implemented |
SF0247 # 01 Y:2002 | 01 | 2002 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $3,149 | $11,455 | n/a |
SF0247 # 02 Y:2002 | 02 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,939 | $0 | n/a |
SF0247 # 03 Y:2002 | 03 | 2002 | USE PHOTOCELL CONTROLS | $4,330 | $6,240 | n/a |
SF0247 # 04 Y:2002 | 04 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,657 | $3,491 | n/a |
SF0247 # 05 Y:2002 | 05 | 2002 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,588 | $3,019 | n/a |