Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

8,673

matching recommendations
Reset
SIC 28 Chemicals And Allied Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SD0235 # 09 Y:1999 09 1999 RECYCLE CLEANING SOLVENT AND REUSE $34,580 $20,000 Not Implemented
SD0235 # 10 Y:1999 10 1999 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $107,143 $115,000 Not Implemented
SD0235 # 11 Y:1999 11 1999 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $21,793 $0 Implemented
SD0235 # 12 Y:1999 12 1999 CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE $4,290 $8,840 Not Implemented
SD0235 # 13 Y:1999 13 1999 CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE $3,960 $0 Implemented
SD0235 # 14 Y:1999 14 1999 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $4,362 $1,078 Implemented
SD0231 # 01 Y:1999 01 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,674 $10,286 Implemented
SD0231 # 02 Y:1999 02 1999 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $7,622 $3,600 Not Implemented
SD0231 # 03 Y:1999 03 1999 SCHEDULE DELIVERIES ACCORDING TO DEMAND $7,020 $0 Implemented
WV0169 # 01 Y:1999 01 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $542 $528 Implemented
WV0169 # 02 Y:1999 02 1999 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,580 $135 Not Implemented
WV0169 # 03 Y:1999 03 1999 DIRECT WARMEST AIR TO COMBUSTION INTAKE $23,520 $16,260 Implemented
WV0169 # 04 Y:1999 04 1999 REPAIR OR REPLACE STEAM TRAPS $100,000 $13,000 Implemented
WV0169 # 05 Y:1999 05 1999 INSULATE BARE EQUIPMENT $146 $74 Not Implemented
WV0169 # 06 Y:1999 06 1999 DIRECT WARMEST AIR TO COMBUSTION INTAKE $8,863 $14,000 Implemented
WV0169 # 07 Y:1999 07 1999 INSULATE BARE EQUIPMENT $176 $44 Not Implemented
WV0169 # 08 Y:1999 08 1999 REDUCE EXCESS STEAM BLEEDING $26,581 $45,000 Not Implemented
WV0169 # 09 Y:1999 09 1999 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $4,154 $7,500 Not Implemented
WV0169 # 10 Y:1999 10 1999 INSTALL WASTE HEAT BOILER TO PRODUCE STEAM $135,268 $200,000 Not Implemented
WV0169 # 11 Y:1999 11 1999 REUSE / RECYCLE/ SELL PAPER PRODUCTS $17,690 $6,000 Not Implemented
WV0169 # 12 Y:1999 12 1999 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $2,647 $11,000 Not Implemented
WV0169 # 13 Y:1999 13 1999 IMPROVE SPACE COMFORT CONDITIONING $20,000 $8,000 Implemented
UM0143 # 01 Y:1999 01 1999 INSTALL OCCUPANCY SENSORS $336 $300 Not Implemented
UM0143 # 02 Y:1999 02 1999 TURN OFF EQUIPMENT WHEN NOT IN USE $461 $0 Not Implemented
UM0143 # 03 Y:1999 03 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $198 $500 Implemented