IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

8,453

matching recommendations
Reset
SIC 28 Chemicals And Allied Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0170 # 04 Y:1989 04 1989 AIR CONDITION ONLY SPACE NECESSARY $4,707 $200 Not Implemented
MA0170 # 05 Y:1989 05 1989 REPAIR OR REPLACE STEAM TRAPS $355 $365 Not Implemented
MA0170 # 06 Y:1989 06 1989 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $119 $150 Not Implemented
MA0170 # 07 Y:1989 07 1989 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $1,248 $2,000 Not Implemented
MA0170 # 08 Y:1989 08 1989 INSTALL TIMERS AND/OR THERMOSTATS $1,999 $180 Not Implemented
WI0075 # 04 Y:1989 04 1989 INSTALL TIMERS AND/OR THERMOSTATS $898 $250 Implemented
WI0075 # 05 Y:1989 05 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $227 $104 Implemented
WI0075 # 06 Y:1989 06 1989 INSTALL STORM WINDOWS AND DOORS $671 $1,144 Implemented
WI0075 # 07 Y:1989 07 1989 IMPROVE LUBRICATION PRACTICES $590 $0 Not Implemented
WI0075 # 08 Y:1989 08 1989 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $291 $700 Not Implemented
WI0075 # 09 Y:1989 09 1989 INSTALL / REPAIR INSULATION ON STEAM LINES $245 $165 Implemented
WI0075 # 01 Y:1989 01 1989 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $3,157 $3,100 Implemented
WI0075 # 02 Y:1989 02 1989 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,866 $500 Not Implemented
WI0075 # 10 Y:1989 10 1989 INSTALL SET-BACK TIMERS $74 $200 Not Implemented
WI0075 # 03 Y:1989 03 1989 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,210 $5,000 Not Implemented
KU0300 # 01 Y:1989 01 1989 INSTALL SET-BACK TIMERS $9,699 $500 Implemented
KU0300 # 02 Y:1989 02 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,850 $1,780 Implemented
KU0300 # 03 Y:1989 03 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,500 $0 Not Implemented
KU0300 # 04 Y:1989 04 1989 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,353 $5,000 Implemented
KU0300 # 05 Y:1989 05 1989 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $1,393 $2,000 Implemented
RU0071 # 01 Y:1989 01 1989 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $15,813 $0 Not Implemented
RU0071 # 02 Y:1989 02 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $360 $295 Implemented
RU0071 # 03 Y:1989 03 1989 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $738 $0 Not Implemented
RU0071 # 04 Y:1989 04 1989 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $554 $117 Not Implemented
RU0071 # 05 Y:1989 05 1989 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $3,352 $50 Implemented