Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

8,673

matching recommendations
Reset
SIC 28 Chemicals And Allied Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WI0061 # 03 Y:1989 03 1989 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $4,969 $0 Implemented
WI0061 # 04 Y:1989 04 1989 IMPROVE LUBRICATION PRACTICES $3,869 $0 Not Implemented
WI0061 # 05 Y:1989 05 1989 RECOVER WASTE HEAT FROM EQUIPMENT $2,896 $3,000 Implemented
WI0061 # 06 Y:1989 06 1989 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,572 $2,100 Not Implemented
WI0061 # 07 Y:1989 07 1989 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,341 $3,000 Implemented
WI0061 # 08 Y:1989 08 1989 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $811 $500 Implemented
WI0061 # 09 Y:1989 09 1989 INSTALL STORM WINDOWS AND DOORS $582 $1,276 Not Implemented
KU0284 # 01 Y:1989 01 1989 USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR $831,745 $1,230,000 Implemented
KU0284 # 02 Y:1989 02 1989 USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER $139,391 $226,000 Implemented
KU0284 # 03 Y:1989 03 1989 INSTALL SET-BACK TIMERS $16,143 $5,856 Implemented
KU0284 # 04 Y:1989 04 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,092 $3,080 Implemented
KU0284 # 05 Y:1989 05 1989 IMPROVE LUBRICATION PRACTICES $2,169 $0 Implemented
KU0284 # 06 Y:1989 06 1989 RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS $618 $0 Implemented
KU0284 # 07 Y:1989 07 1989 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $931 $1,018 Implemented
KU0284 # 08 Y:1989 08 1989 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $169 $0 Implemented
OR0057 # 01 Y:1989 01 1989 INCREASE AMOUNT OF CONDENSATE RETURNED $2,420 $870 Implemented
OR0057 # 02 Y:1989 02 1989 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $201 $145 Implemented
OR0057 # 03 Y:1989 03 1989 OPTIMIZE PLANT POWER FACTOR $6,061 $5,850 Implemented
OR0057 # 04 Y:1989 04 1989 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $308 $389 Implemented
OR0057 # 05 Y:1989 05 1989 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $1,219 $1,903 Not Implemented
OR0057 # 06 Y:1989 06 1989 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $6,972 $28,690 Not Implemented
OR0057 # 07 Y:1989 07 1989 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $2,159 $6,871 Not Implemented
AM0055 # 01 Y:1989 01 1989 IMPROVE LUBRICATION PRACTICES $1,260 $0 Not Implemented
AM0055 # 02 Y:1989 02 1989 REDESIGN FLOW TO MINIMIZE MASS TRANSFER LENGTH $917 $0 Not Implemented
AM0055 # 03 Y:1989 03 1989 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE $547 $500 Implemented