Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
333
matching recommendationsSIC | 28 | Chemicals And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0893 # 03 Y:2012 | 03 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $41,547 | $70,000 | Not Implemented |
GT0893 # 02 Y:2012 | 02 | 2012 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $4,070 | $4,000 | Not Implemented |
GT0893 # 01 Y:2012 | 01 | 2012 | USE SYNTHETIC LUBRICANT | $14,406 | $0 | Not Implemented |
GT0871 # 03 Y:2010 | 03 | 2010 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $40,118 | $23,620 | Implemented |
GT0871 # 08 Y:2010 | 08 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,500 | $12,000 | Not Implemented |
GT0871 # 07 Y:2010 | 07 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,563 | $17,696 | Implemented |
GT0871 # 06 Y:2010 | 06 | 2010 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $16,535 | $11,000 | Not Implemented |
GT0871 # 05 Y:2010 | 05 | 2010 | UPGRADE CONTROLS ON COMPRESSORS | $3,635 | $22,000 | Not Implemented |
GT0871 # 04 Y:2010 | 04 | 2010 | INSTALL DE-AERATOR IN PLACE OF CONDENSATE TANK | $119,576 | $25,000 | Not Implemented |
GT0871 # 02 Y:2010 | 02 | 2010 | INCREASE AMOUNT OF CONDENSATE RETURNED | $20,114 | $23,200 | Not Implemented |
GT0871 # 01 Y:2010 | 01 | 2010 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,860 | $768 | Implemented |
GT0854 # 09 Y:2008 | 09 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,015 | $35,125 | Implemented |
GT0854 # 08 Y:2008 | 08 | 2008 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $14,260 | $23,000 | Implemented |
GT0854 # 07 Y:2008 | 07 | 2008 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $9,141 | $10,000 | Not Implemented |
GT0854 # 06 Y:2008 | 06 | 2008 | REDUCE EXCESSIVE BOILER BLOWDOWN | $4,690 | $0 | Not Implemented |
GT0854 # 05 Y:2008 | 05 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $13,990 | $80,000 | Not Implemented |
GT0854 # 04 Y:2008 | 04 | 2008 | REPAIR OR REPLACE STEAM TRAPS | $25,424 | $5,000 | Implemented |
GT0854 # 03 Y:2008 | 03 | 2008 | INCREASE AMOUNT OF CONDENSATE RETURNED | $5,970 | $2,500 | Not Implemented |
GT0854 # 02 Y:2008 | 02 | 2008 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,745 | $3,000 | Implemented |
GT0854 # 01 Y:2008 | 01 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $2,568 | $700 | Implemented |
GT0833 # 08 Y:2006 | 08 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $36,891 | $62,250 | Not Implemented |
GT0833 # 07 Y:2006 | 07 | 2006 | $6,204 | $0 | Implemented | |
GT0833 # 06 Y:2006 | 06 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,653 | $550 | Not Implemented |
GT0833 # 05 Y:2006 | 05 | 2006 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $29,400 | $0 | Implemented |
GT0833 # 04 Y:2006 | 04 | 2006 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $9,806 | $18,000 | Not Implemented |