Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
42
matching recommendationsSIC | 281 | Industrial Inorganic Chemicals |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0743 # 10 Y:2006 | 10 | 2006 | REDUCE EXCESSIVE BOILER BLOWDOWN | $15,000 | $0 | Implemented |
UD0743 # 20 Y:2006 | 20 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,342 | $500 | Implemented |
UD0743 # 21 Y:2006 | 21 | 2006 | UPGRADE CONTROLS ON COMPRESSORS | $831 | $0 | Implemented |
UD0704 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $668 | $700 | Implemented |
UD0704 # 01 Y:2004 | 01 | 2004 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $10,368 | $0 | Implemented |
UD0704 # 07 Y:2004 | 07 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $223 | $500 | Implemented |
UD0704 # 06 Y:2004 | 06 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $504 | $0 | Implemented |
UD0704 # 03 Y:2004 | 03 | 2004 | UPGRADE CONTROLS ON COMPRESSORS | $846 | $900 | Implemented |
UD0242 # 05 Y:1988 | 05 | 1988 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $124,465 | $0 | Implemented |
UD0242 # 03 Y:1988 | 03 | 1988 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,684 | $750 | Implemented |
UD0241 # 06 Y:1988 | 06 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,574 | $1,000 | Implemented |
UD0241 # 01 Y:1988 | 01 | 1988 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $8,400 | $600 | Implemented |
UD0215 # 04 Y:1987 | 04 | 1987 | RECOVER WASTE HEAT FROM EQUIPMENT | $265 | $300 | Implemented |
UD0215 # 02 Y:1987 | 02 | 1987 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $662 | $140 | Implemented |
UD0215 # 01 Y:1987 | 01 | 1987 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $4,028 | $0 | Implemented |
UD0186 # 03 Y:1986 | 03 | 1986 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $23,369 | $26,000 | Implemented |
UD0186 # 01 Y:1986 | 01 | 1986 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $7,459 | $0 | Implemented |